A/C

 – Air conditioning also 

referred to as A/C. A system 

or device for reducing the 

temperature and humidity, in 

a space.

AHAM

 – Acronym for Association 

of Home Appliance Manufacturers. 

AHAM produces the official rating 

for dehumidifiers. 

BTU

 – British Thermal Unit. A 

single BTU is the amount of energy 

required to cool or heat a pound of 

water one degree Fahrenheit. 

Condenser

 – The unit used to 

condense a substance from a 

gaseous state to liquid by cooling 

it. Condensers are generally 

recognized as heat exchangers. In 

the case of air conditioners they 

extract the inside heat from the 

interior of the air conditioner to 

the outside air. Often referred to as 

“the outdoor unit.”

Dehumidifier

 – Also called, 

dehums. Dehumidifiers remove 

humidity and are used to keep a 

rooms humidity levels in check. 

Maintaining correct humidity will 

ensure a healthy crop. Too much 

humidity will cause molds, rot and 

devastate your crop.

Digital Inverter Compressor

 – 

A digitally controlled compressor 

that converts AC voltage to DC 

voltage to control compressor 

speed. The inverter allows precise 

throttle control of the conditioning 

unit based on the load or need. 

Inverter units are quieter, more 

efficient and last longer. 

Ductless Mini-Split

 – An air 

conditioner or heat pump that 

requires no duct work to function. 

The unit hangs on the wall or 

ceiling and cools or heats the 

surrounding area. 

Evaporator

 – The indoor portion 

of the heat pump or air conditioner. 

In a mini-split system this hangs on 

the wall or ceiling and provides the 

heating or cooling of the space. 

H/P 

– Heat Pump. A unit that can 

operate as both an air conditioner 

or a heater. When it’s cold outside 

a heat pump extracts the outside 

heat and transfers it inside. When 

it’s warm outside, it reverses 

directions and acts like an air 

conditioner, removing heat. A 

heat pump moves heat instead 

of generating it, giving you more 

energy efficiency. 

HSPF

 – Heating Seasonal 

Performance Factor. The greater 

the number/rating the more 

efficient the heating. A 10 HSPF, 

for example is a very good rating.

Humidifier

 – Humidifiers use 

water to put humidity in the 

growing space. Many plants we 

grow indoors are accustomed 

to growing outdoors in tropical 

areas where humidity is high. Also 

certain parts of the country are 

drier than others so you will need 

to add humidity.

Line Set

 – Insulated copper tubing 

used to connect the evaporator 

and condenser. The refrigerant 

travels back and forth through the 

line set between the evaporator 

and condenser to create either 

cooling or heating. 

R-410

 – A type of refrigerant. 

Unlike alkyl halide refrigerants, 

R-410A (which contains only 

fluorine) does not contribute 

to ozone depletion. Because of 

that attribute it’s preferred and 

used more broadly instead of 

R-22 which are phased out. R-410 

refrigerants allow for higher SEER 

ratings therein reducing power 

consumption and improving unit 

efficiency. 

SEER

 – Seasonal Energy Efficiency 

Ratio. The greater the SEER rating, 

the more efficient the cooling 

system. The minimum SEER rating 

allowed by the Federal Government 

is 14. 

Ton

 – The size of air conditioning 

unit (heating or cooling) is 

common referred to in “tons”. A 

one ton unit, for example, is 12,000 

BTU’s. A two ton, 24,000 BTU’s, 

etc. This was arrived at using a 

standard of how long it would take 

to melt ice. A one ton unit takes 

12,000BTU’s of heat one hour to 

melt a ton of ice. 

VFD 

– Variable Frequency Drive. 

The VFD is a an electrical device 

that’s used to control the speed 

and torque of an air conditioning 

motor, like those used in an 

inverter compressor.

bo

GLOSSARY OF TERMS

NOTES

_______________________________________________________ 

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

_______________________________________________________

Summary of Contents for 700807

Page 1: ...IONER USER MANUAL This manual only describes the installation of the indoor unit When installing the outdoor unit refer to the installation manual of outdoor unit 700807 700808 PRO DUAL MINI SPLIT I N...

Page 2: ...sonal property and also poses a personal safety hazard on your purchase of Ideal Air s Pro Mini Split indoor wall mount unit We re proud to offer this product and believe it s the very best in its cla...

Page 3: ...Call your dealer for instructions to avoid electric shock fire or injury DO NOT insert fingers rods or other objects into the air inlet or outlet This may cause injury since the fan may be rotating at...

Page 4: ...ed use DO NOT climb onto or place objects on top of the outdoor unit DO NOT allow the air conditioner to operate for long periods of time with doors or windows open CAUTION UNIT SPECIFICATIONS AND FEA...

Page 5: ...erature 18 43 C 64 109 F 7 24 C 19 75 F 11 43 C 52 109 F 7 43 C 19 109 F For models with low temp cooling systems 18 43 C 64 109 F 18 54 C 64 129 F For special tropical models 18 54 C 64 129 F For spe...

Page 6: ...hour and will increase an additional 1 C 2 F after another hour When in HEAT mode the unit will decrease the temperature by 1 C 2 F after 1 hour and will decrease an additional 1 C 2 F after another h...

Page 7: ...d Press the MANUAL CONTROL button again to activate FORCED COOLING mode Press the MANUAL CONTROL button a third time to turn the unit off Close the front panel The manual button is intended for testin...

Page 8: ...ts previous display To reset the reminder press the LED button on your remote control 4 times or press the MANUAL CONTROL button 3 times If you don t reset the reminder the CL indicator will flash aga...

Page 9: ...ached at which point the unit turns off the compressor The unit will continue operating when the temperature fluctuates again The indoor unit emits white mist In humid regions a large temperature diff...

Page 10: ...d description of the unit malfunction as well as your model number The indoor unit makes noises A squeaking sound may occur after running the unit in HEAT mode due to expansion and contraction of the...

Page 11: ...eople computers electronics etc Reduce amount of heat sources Low refrigerant due to leak or long term use Check for leaks re seal if necessary and top off refrigerant SILENCE function is activated op...

Page 12: ...er off The unit starts and stops frequently There s too much or too little refrigerant in the system Check for leaks and recharge the system with refrigerant Incompressible gas or moisture has entered...

Page 13: ...or unsorted municipal waste When disposing of this appliance you have the following options Dispose of the appliance at designated municipal electronic waste collection facility SPECIAL NOTICE Disposi...

Page 14: ...greater the number rating the more efficient the heating A 10 HSPF for example is a very good rating Humidifier Humidifiers use water to put humidity in the growing space Many plants we grow indoors a...

Page 15: ...____________________ _______________________________________________________ _______________________________________________________ _______________________________________________________ ___________...

Page 16: ...answers to most common questions and a complete technical support library please visit www ideal air com All design and specifications herein are subject to change without notice for product improveme...

Reviews: