MiniSmart II
29
Get MSR Data control
Output Body is 49 72 03 <Len_L of Control Data> <Len_H of Control Data> <m bytes
Control Data>
Where:
<m bytes Control Data>
Input Body is 72 49 03 <ACK> <Len_L of ACK Data> <Len_H of ACK Data> <n bytes
ACK Data>
Where:
<n bytes ACK Data>
n bytes MSR Data
Smart Card Group – Set/Get Commands Misc.
Set Key Type for Data encryption Key (ICC DUKPT Key)
Command Body is 72 53 01 01 01 <Option>
•
Length of Total timeout for Swipe MSR Card. – 2 bytes (Little-endian)
•
Total timeout for Swipe MSR Card, in second, (Little-endian), default is 30
seconds.
•
Length of Display Message Language. - 2 bytes (Little-endian)
•
Display Message Language, 2 byte
EN - English (default)
ES - Spanish
ZH - Chinese
FR – French
…
•
Length Display Message Control - 2 bytes (Little-endian)
•
Display Message Control: <Line><Message><0x1C>
<Line> - lower 7 bits is for line number: Display line number (1-First Line, n-nth
Line), Maximum 16 lines.
The MSB need be 1: is to indicate following message is Message ID.
<Message> - Message ID.
Message ID: 1 byte, check
LCD Foreign Language Mapping Table. Normal Value is
19.
<0x1C> - separator
•
If Menu Display, Length of Menu value (If Normal Display, Length of Key (Get
Function))
•
If Menu Display, Menu value, sequence number of selected line, hex format (If
Normal Display, ASCII format (‘E’ is Enter, ‘C’ is Cancel))