ID-AL EventPlayer mkII - EP220 and EP230 - Quick Start Guide V1.0
7 Show Control
The EventPlayer mkII can play Show Control sequences stored on the storage device. A sequence can be played
alone or simultaneously with a WAV or MP3 file. It controls the state of the 512 channels of the DMX512 output and
of the MOSFET outputs with a resolution of 50 ms.
•
The Show Control sequences are stored in
SC2
files, to generate with the Show Control Editor software.
•
Once the
SC2
files have been created, they must be placed in the folders of the storage device as explained
in the chapter Preparation of the Storage Device. To associate a Show Control file with an audio file, give the
same filename to both files, except for their extensions (e.g.:
FirtShow.sc2
and
FirtShow.mp3
).
Note:
in the Show Control Editor software, use the
U/D
connector of the EP230 to preview the DMX512 channels
in real time.
8 Scheduler
The player can be programmed thanks to the Scheduler, according to a timetable provided on the storage device. It
manages the playback thanks to folder playback, stop and resume commands.
•
The timetable is stored in a
TM2
file, to generate with the Scheduler software (e.g.:
scheduler.tm2
).
•
Once the
TM2
file has been created, it must be placed at the root of the storage device as explained in the
chapter Preparation of the Storage Device.
9 Web Server
To control and configure the player over Ethernet, use its embedded web server. In a web browser:
•
Enter the HTTP address of the player (e.g.:
http://192.168.0.104
).
•
On the
Login
web page, enter the username (
User
) and the password (
Password
) of the embedded web
server (by default: username =
idalweb
and password =
idalweb
).
•
In order to log out, click on
Sign Out
.
Note:
for maximum security, it is highly recommended to set proper usernames and passwords on the
Configuration
page of the web server.
10 FTP Server
To manage the files and folders of the storage device over Ethernet, use the embedded FTP server of the player. In
an FTP client application, enter the following settings:
•
Host: IP address of the player (e.g.:
192.168.0.104
).
•
Port:
21
.
•
User: username of the embedded FTP server (by default:
idalftp
).
•
Password: password of the embedded FTP server (by default:
idalftp
).
•
Limit the number of simultaneous connections to
1
.
Note:
for maximum security, it is highly recommended to set proper usernames and passwords on the
Configuration
page of the web server.
11 Firmware Update
Start the player with an
EVENT.bin
firmware file placed at the root of a microSD card formatted as FAT32.
Note:
the update by USB flash drive is not supported.
12 Factory Reset
Start the player by pressing the front panel clickable knob. When the LCD displays
, release the
clickable knob and let the player boot up.
© 2018, Waves System - 7 impasse de La Ville en Bois, 44830 Bouaye, France - Phone: +33 (0)2 40 78 22 44 - [email protected]