background image

ID-AL ChronoPlayer - Quick Start Guide V1.0

 5  User Interface

The user can interact with the player thanks to the LCD display and the  

Volume/-Menu-

 clickable knob on the 

front panel:

Player status:

Rotation: volume control.

Click: toggle PLAY/STOP.

Long push (> 3 s): setup menu.

Volume control:

Rotation: volume control.

Click: back to the status 
display.

Setup   menu:   time   zone,   date, 
and time:

Rotation: selection.

Click: validation.

 6  Reference

 6.1  Folder and File Tags

Tag

Folder File

Parameter

Description

Min Max Default

[Jxxx]

000 999

Jump to the 

xxx

 folder at the end of the playback.

[RET]

Return to the previous folder at the end of the playback.

[RND]
[SEQ]

[RND]

Random or sequential folder playback mode.

[V+xx]
[V-xx]

00

64

00

Relative volume of the folder or of the file.

[NT]

Block all the commands from the inputs, and the folder change commands from the RS-232 
link and the Scheduler.

[RSxxx]

001 999

Send the 

#xxx

 RS-232 frame from the 

serial.txt

 file.

[WHL]

Play the folder while the assigned input combination remains activated.

[NXTxxx]

001 999

Play the next 

xxx

 audio files each time the folder is played.

 6.2  Configuration File

The 

config.txt

 configuration file is a raw text file placed at the root of the storage device. Each line can define a 

parameter of the player according to the following table:

Parameter Definition

Valid Values

Default Value

Description

#ID:xxx

001 to 127

001

RS-232 ID of the player.

#VOLUME:xx

00 to 64

Last used value

Volume of the player on startup.

#RS_MONITORING:x 0: no monitoring

1: “Daisy Chain” mode
2: “Monitoring” mode
3: “Advanced Monitoring” mode

0

Monitoring mode of the RS-232 serial link.

#BOOT:xxx

000 to 999

000

Folder to play on startup.

#INPUTxx:cmd

xx: 01 to 15
cmd: see the commands table

FOLDER0xx

Commands assigned to the input contact 
combinations.

#BUTTONx:cmd

x: 1 or 2
cmd: see the commands table

BUTTON1:VOLUME_MINUS
BUTTON2:VOLUME_PLUS

Commands assigned to the special buttons of the 
infrared remote control.

#BAUDRATE:xxxxx

9600, 19200, 38400

19200

Baud rate of the RS-232 serial port.

© 2016, Waves System - Impasse de La Ville en Bois, 44830 Bouaye, France - Phone: +33 (0)2 40 78 22 44 - [email protected]