background image

ICWUSA.com, Inc.

If you have any questions, please call 1-800-558-4435

MD ARM INSTALLATION INSTRUCTIONS

MD ARM INSTALLATION INSTRUCTIONS - rev  11/13/2012 mf

page 3

ATTACH PARALINK KEYBOARD TRAY

Loosen  knob  to  adjust  Paralink. 

Adjust horizontally for keyboard tray 

and  vertically  for  monitor.  Tighten 

knobs when in desired position.

Attach the keyboard tray 

to  the  Keyboard  Mount 

using the supplied 5/16-

18 socket head screw.

ATTACH KEYBOARD TO MONITOR

Attach  the  Paralink 

Keyboard  Mount  to 

the  Monitor  Mount 

by  using  the  3/8-16 

screw and lock washer 

provided

ATTACH FLIPUP TO PLATE

Attach the tray 

fl ip-up assembly 

to the fl ip-up plate 

using the provided 

fl at head screws 

and hex key.

IF USING PARALINK KEYBOARD TRAY

IF USING ULTRA KEYBOARD TRAY

ADJUST MD ARM RESISTANCE

Using  the  3/16” 

t - h a n d l e   h e x 

wrench  provided, 

turn the screw in the 

MD arm clockwise 

to lighten the arm’s 

load resistance, or 

counter-clockwise 

to increase the load 

resistance.

ATTACH COVERS TO MD ARM

After  lowering  the  arm  to  the 

down  position,  slide  on  the 

lower  cover.  Using  a  Phillips 

head 

screwdriver 

(NOT 

POWER  TOOLS),  reattach  the 

four screws attaching the lower 

cover.

Attach  the  top  cover  by 

reattaching  the  four  top  cover 

screws  using  a  Phillips  head 

screwdriver  (NOT  POWER 

TOOLS).

WARNING - PINCH POINT:

Keep  fi ngers  away  from  the 

inner arm area where the gas 

spring is located.