ICT ND-500G Operation Manual Download Page 8

- 10 -

Machine number   

Pulse Setting 

Machine 0 

Machine 1 

Machine 2 

Machine 3 

Machine 4 

Machine 5 

Machine 6 

Machine 7 

SW4 

SW5 

SW6

10 

20 

50 

100 

SW1 

ON 

ON 

OFF 

OFF 

ON  

ON  

OFF 

OFF 

ON 

ON 

OFF 

OFF 

OFF 

ON 

SW2 

SW3

ON 

ON 

ON

ON

ON 

ON 

ON

ON

OFF 

OFF 

ON

ON

OFF 

OFF 

ON

ON

ON 

ON 

OFF

OFF

ON 

ON 

OFF

OFF

OFF 

OFF 

OFF

OFF

OFF 

OFF 

OFF

OFF

OFF 

ON 

ND-500G function setting 

2

. Front LED Status

    (1) Green   : Normal

    (2) Red      : Error 

(no notes or 2 notes together)

    (3) Orange : Needs to refill notes

    (4) Off        : Dispensing note

3. Front Button

    Reset Key : Press this button to restart the note dispenser. No need 

to turn the power off and on again.

                        

 

 

 

 

 

 

 

1. Dipswitch Setting

 

ND - 500G

N
D
-

5
0
0
G

Note Thickness Calibration Mode Setting 

Credit Active 

Credit Width

Dispense Mode

Normal Lo

50 ms

Calibration Mode

Normal Hi

1 sec

SW7

SW9

SW10

OFF 

OFF 

OFF 

ON 

ON 

ON 

Note Dispense Mode 

Hopper Mode

Pulse Mode

SW8

OFF 

ON 

- 11 -

4. Note Dispensing Mode

   (1) Pulse Mode : When the Note Dispenser receives enough pulses 

( set by Dipsw 4~6) it will dispense one note.

                                

 

 

 

   

 

 

 

   (2) Hopper Mode : The Note Dispenser will begin to dispense notes 

when it receives the dispense command, and will

                                

   

 

 

 

 

 

 

not stop dispensing until it receives the stop

                                 

 

 

 

   

 

 

 

 

command.

                                 

 

   (3) RS-232 Mode : It receives commands from RS-232 signal to 

dispense notes.

                                 

 

 

(Max. 8 note dispensers can be linked together)

                                

 

  

 

 

   

 

                 

Optional : Use cable 3TP-AA221-B4 to connect directly 

to PC (page 16).

                                  

 

 

 

  

           

(1) Under pulse mode, Dipsw 1~3 are not used

(2) Under Hopper mode, Dipsw 1~6 are not used

            

 

 

 

 

 

 

 

 

(3) Under RS-232 mode, Dipsw 4~6 are not used

            

 

 

 

 

 

 

 

 

5. Trouble Shooting

   (1) If the front LED is orange, it means the quantity of notes in the 

Dispenser is not enough; you can solve this problem by filling more

        

   

 

 

 

 

 

 

 

 

 

bills.

        

   (2) If the front LED is red, it means:

       A. Out of Notes        : Refill the notes in and press the reset button.

       B. Dispensing Error : This happens when an error has occurred 

during dispensing process, it can be either the

                                         

 

 

   

 

 

 

 

dispending speed is too slow or it's dispensing

                                         

 

   

 

 

 

 

 

2 bills at the same time. Just check if there's

                                           

 

 

 

 

 

 

   

 

any note jammed in the dispenser, and then

                                         

 

 

   

 

 

 

 

press the reset button.

                                         

 

 

 

 

       C. When the front LED is OFF, means the note is jammed in the 

Note Dispensing gate, and has blocked the sensor. In this case

            

 

 

 

 

 

 

 

 

 

 

 

just remove the jammed note and it will continue working normally.

            

 

 

 

 

 

   

 

 

 

PS.

ND - 500G

N
D
-

5
0
0
G

Summary of Contents for ND-500G

Page 1: ...Operation Manual ND 500G 2003 International Currency Technologies Corporation Vol 4 0 Part Number H4552C...

Page 2: ......

Page 3: ...h and length 6 How to adjust thickness the dispenser bezel 8 ND 500G function setting 10 1 DIP Switch Settings 10 2 Front LED Status 10 3 Front Button 10 4 Note Dispensing Mode 11 5 Trouble shooting 1...

Page 4: ...5mm 100mm 175mm Length 0 1mm 0 2mm Thickness min max 2 Note Capacity Approx 500 notes 3 Voltage 12VDC 10 4 Power Consumption 0 15A standby 0 75A peak 5 Note Dispensing Time Approx 1 sec 6 Place in Use...

Page 5: ...s in 3 Put the note pressure plate back on top of the notes 4 Put back the top cover and lock it 5 Press the front button to reset the note dispenser 6 In the event that the dispenser runs out of note...

Page 6: ...40 6 67 8 26 7 61 6 24 3 52 8 20 8 Unit mm inch Note partition board 1 Note partition board 2 ND 500G ND 500G How to adjust the width and length 1 Use the note partition board 1 to adjust the length a...

Page 7: ...Calibration Mode 4 Turn the power on and dispensing should start automatically observe the front LED for the operation status of the dispenser 5 Red light indicates that the speed of dispensing is too...

Page 8: ...The Note Dispenser will begin to dispense notes when it receives the dispense command and will not stop dispensing until it receives the stop command 3 RS 232 Mode It receives commands from RS 232 si...

Page 9: ...sing process is successful ND 500G will reply as follow If the note dispensing process fails ND 500G will reply as follow If the note dispensing process 1 bill and fails ND 500G will reply as follow N...

Page 10: ...er request all machines to dispense 5 bill After request command user needs to poll the all machines status And check all machines status as follow example 2 STX STX STX STX STX STX M S M S M S M S M...

Page 11: ...16 ND 500G 50ms or 1 sec 50ms or 1 sec ND 500G 17 ND 500G ND 500G 50ms or 1 sec...

Page 12: ...18 ND 500G 50ms or 1 sec ND 500G...

Reviews: