ICT MP306 Operation Manual Download Page 1

DocRef: Ver1.

3

MP

3

06 Moisture Probe

 

Operation Manual

ICT International Pty Ltd

PO Box 503

Armidale NSW 2350

AUSTRALIA

Phone: 

[61] 2-6772-6770

Fax: 

[61] 2-6772-7616

Email: 

[email protected]

     

Web: 

www.ictinternational.com

Summary of Contents for MP306

Page 1: ...3 MP306 Moisture Probe Operation Manual ICT International Pty Ltd PO Box 503 Armidale NSW 2350 AUSTRALIA Phone 61 2 6772 6770 Fax 61 2 6772 7616 Email sales ictinternational com au Web www ictinterna...

Page 2: ...eration 4 2 3 1 Theory 4 2 3 2 Results 5 2 3 3 Definitions 6 2 4 Calibration 7 2 4 1 General 7 2 4 2 Linear Calibration 7 2 4 3 Polynomial Calibration 7 2 4 4 Polynomial Lookup Table 8 2 5 Wiring 8 2...

Page 3: ...lly connected to a set of chrome extension rods which have a T handle on the end The extension rods enable the operator to insert the needles of the MP306 into the soil surface without bending over an...

Page 4: ...ed to be recharged within about 30 days as it will self discharge in this time 2 3 Theory of Operation 2 3 1 Theory The MP306 has a high frequency moisture detector which uses the standing wave princi...

Page 5: ...s obtained from comparative testing of the MP306 in prepared soil samples for a wide range of agricultural soils MP306 OVEN 0 5 10 15 20 25 30 35 40 Soil Sample Volumetric Soil Water MP306 1 0136x 0 4...

Page 6: ...ic Soil Water Percent as a Standard 2 3 3 Definitions Gravimetric Soil Water Content is de ned as G Mw Where Mw is the mass of water in the soil sample Ms and Ms is the total mass of the dry soil samp...

Page 7: ...entists or regulatory authorities may wish to calibrate the MP306 to verify the data measured In these cases it is simply necessary to compare the MP306 output in mV 0 1 mV to the VSW from the soil sa...

Page 8: ...00 1045 18 93 15 00 415 9 93 75 00 1055 19 07 20 00 510 11 285 80 00 1065 19 21 25 00 610 12 71 85 00 1070 19 28 30 00 720 14 285 90 00 1080 19 43 35 00 825 15 785 95 00 1095 19 64 40 00 895 16 785 1...

Page 9: ...s 7 18 V DC unregulated Power consumption 32 mA typical Output signal 0 1 V for 0 50 VSW Response Time Less than 0 5 seconds 5 seconds approximately from power up Mechanical Total length 215 mm Diamet...