background image

PROBLEM

CAUSE

SOLUTION

Link LED on LEX 
unit is on, Host 
LED on LEX unit 
is off.

•  The host computer is not 

   powered on.

•  The LEX unit is not connected

   to the computer (when used
   with the optional LEX AC 
   LEX AC adapter).

•  The computer does not

 

   support USB hubs.

•  The Ranger 2204 is 

 

   malfunctioning.

1.  Disconnect all USB devices from the REX unit.

2.  Disconnect the LEX unit from the computer.

3.  Disconnect the REX unit from the AC power 

adapter.

4.  Reconnect the LEX unit to the computer.

5.  Reconnect the REX unit to the AC power 

adapter.

6.  In the Universal Serial Bus controller’s section
     of Device Manager, check that the Ranger 2204 
     is recognized as a “Generic USB Hub”.

Ranger 2204 
system was 
working, but the 
Host LED on LEX/
REX units are 
suddenly blinking.

•  The REX unit is in suspend

 

   mode. The operating system 
   may put the Ranger 2204 
   in suspend mode when the 
   computer is put into a 
   Suspend/Standby state or 
   when no USB devices are  
   attached. 

1.  Recover/Resume the operating system from 
     Suspend/Standby mode (see your operating  
     system’s documentation).

2.  Attach a USB device to the REX.

All LEDs on both 
the LEX/REX units 
are on, but the USB 
device does not 
operate correctly 
or is detected 
as an “Unknown 
Device” in the 
operating system.

•  The USB device is 

   malfunctioning.

•  The computer does not 

   recognize the USB device.

•  The application software for 

   the device is not operating.

•  The Ranger 2204 is

 

   malfunctioning.

1.  Disconnect the Ranger 2204 from the computer.

2.  Connect the USB device directly to the USB port 
     on the computer.

3.  If the device does not operate properly, consult
     the user documentation for the device.

4.  Update your system BIOS, chipset, or USB Host 
     controller drivers from your System/Mother-
     board manufacturer’s website.

5.  If the device operates properly when directly 
     connected to the computer, connect another 
     device (of a different type) to the Ranger 2204. 
     Connect the Ranger 2204 to the computer.

6.  If the second device does not operate, the 
     Ranger 2204 may be malfunctioning.  
     Contact technical support for assistance.

7.  If the second device operates properly, the
     first device may not be compatible with
     the Ranger 2204. 

9

Summary of Contents for USB 2.0 Ranger 2204

Page 1: ...USB 2 0 Ranger 2204 4 port USB 2 0 100m Cat 5e Extender System User Guide ...

Page 2: ...lity that the USB 2 0 Ranger 2204 to which this declaration relates is in conformity with European Standard EN 55022 EN 55024 EN 61000 3 2 and EN 61000 3 3 IC Statement This Class B digital apparatus complies with Canadian ICES 003 2014 Icron Technologies Corporation All rights reserved Icron Technologies Corporation the Icron Technologies Corporation logo and the Icron Technologies Corporation pr...

Page 3: ... Description 5 Installation Guide 6 Installing the LEX Unit 6 Installing the REX Unit 6 Connecting the LEX Unit to the REX Unit 7 Checking the Installation 7 Connecting a USB Device 8 Compatibility 8 Troubleshooting 8 Specifications 11 Warranty Information 12 Obtaining Warranty Service 13 Contacting Technical Support 13 Technical Glossary 14 ...

Page 4: ...e product USB 1 1 or 2 0 compatible computer host computer with a USB compliant operating system USB 1 1 or 2 0 compatible device s Cat 5e Unshielded Twisted Pair UTP cable with two RJ45 connectors if using surface cabling or Cat 5e cable with two information outlets and two Cat 5e patch cords with RJ45 connectors if using premise cabling All references to Cat 5e cable in this document represent t...

Page 5: ...hat the Ranger 2204 system is properly enumerated on the host computer LED blinks when in a suspended state 4 Activity LED Amber Indicates activity when data transmission is active between LEX and REX units LED blinks intermittently with or without a USB device connected When the LEX and REX are in suspend mode the LED is off 5 Power Port optional Not required in normal operation An optional 5V po...

Page 6: ...ts to draw more than 500mA of current 3 Power LED Blue LED turns on when power is supplied LED is off when no power is supplied 4 Link LED Green Indicates a valid ExtremeUSB link is established between the LEX and REX over Cat 5e cable LED turns on when link between LEX and REX is established LED is off when there is no link between LEX and REX 5 Host LED Green Indicates that the Ranger 2204 syste...

Page 7: ...ons with Cat 5e information outlets located near both the computer and the USB device s and the total length including patch cords is no more than 100m Installing the LEX Unit 1 Place the LEX unit near the computer 2 Install the supplied USB cable between the LEX and USB port on the host computer Installing the REX Unit 1 Place the REX unit near the USB device s in the desired remote location 2 Pl...

Page 8: ...e between the LEX and REX units is not installed properly or is defective 2 For Windows users 2000 XP Vista Windows 7 Windows 8 open Device Manager to confirm that the Ranger 2204 has installed correctly Expand the entry for Universal Serial Bus controllers by clicking the sign If the Ranger 2204 has been installed correctly you should find it listed as a Generic USB Hub 3 For Mac OS X users open ...

Page 9: ...ctions please contact Technical Support at icron com support for further assistance PROBLEM CAUSE SOLUTION All LEDs on LEX unit are off The LEX unit is not receiving enough power from the USB port or the optional LEX AC adapter 1 Ensure the USB connection between the LEX and host computer is properly installed 2 Move the USB connector to another USB port on the host computer All LEDs on REX unit a...

Page 10: ...ng system from Suspend Standby mode see your operating system s documentation 2 Attach a USB device to the REX All LEDs on both the LEX REX units are on but the USB device does not operate correctly or is detected as an Unknown Device in the operating system The USB device is malfunctioning The computer does not recognize the USB device The application software for the device is not operating The ...

Page 11: ...ocumentation and power your USB device with the additional USB device manufacturer supplied power supply if available Device LED is orange and extenders are no longer functioning Overcurrent condition has occurred because USB device draws more power than can be supplied per USB specification 500mA 1 Power cycle REX LED Host and LINK LEDs on LEX REX units blink intermittently Firmware mismatch betw...

Page 12: ...e jack System Shipping Weight 2 0 lbs 0 9 kg LOCAL EXTENDER LEX USB Connector 1 x USB Type B Receptacle Link Connector 1 x RJ45 Dimensions 100 mm x 76 mm x 26 mm 3 94 x 2 99 x 1 02 Enclosure Material Silver Anodized Aluminum REMOTE EXTENDER REX USB Connector 4 x USB Type A Receptacles Link Connector 1 x RJ45 Dimensions 100 mm x 76 mm x 26 mm 3 94 x 2 99 x 1 02 Enclosure Material Silver Anodized Al...

Page 13: ...r is longer These remedies are void if failure of the hardware has resulted from accident abuse or misapplication Limitation of Liability The hardware warranty set forth in this agreement replaces all other warranties Icron Technologies Corporation expressly disclaims all other merchantability and fitness for a particular purpose and non infringement of third party rights with respect to the hardw...

Page 14: ...d or replaced item will be shipped to you at Icron Technologies Corporation s expense not later than thirty days after Icron Technologies Corporation receives the defective product Address the returned product to RMA Coordinator Icron Technologies Corporation 4664 Lougheed Highway Suite 221 Burnaby BC V5C 5T5 Canada Contacting Sales Email sales icron com Tel 1 604 638 3920 Contacting Technical Sup...

Page 15: ...erface is what connects the network cable Cat 5e to the LEX unit and REX unit You may use either the T568A scheme Table 1 or the T568B scheme Table 2 for cable termination as the USB 2 0 Ranger 2204 uses all four pairs of the cable RJ45 connectors are sometimes also referred to as 8P8C connectors Note that any given cable must be terminated using the same T568 scheme on both ends to operate correc...