background image

 

 

7

 

Please refer to the protocol sheets for detailed information.  

Reserved  

Baud rate 

Parity 

120

  Connect  to the 120

 

ON 

Please note the speed dome cans automatically recognize the DH-SD, PELCO-D. PELCO-P. Usually 

you do not need to set. 

Please refer to the baud rate sheet for detailed information. 

Baud Rate 

OFF 

OFF 

9600bps 

ON 

OFF 

4800bps 

OFF 

ON 

2400bps 

ON 

ON 

1200bps 

Please refer to the parity setup sheet for detailed information. 

Parity  

OFF 

OFF 

NONE 

ON 

OFF 

EVEN 

OFF 

ON 

ODD  

ON 

ON 

NONE 

2.2

2.2

2.2

2.2

 

Set address dial switch 

Set address dial switch 

Set address dial switch 

Set address dial switch     

 

SW2 

 

Figure 2-3 

The encode mode adopts binary system. 1 to 8 is the valid bit. The highest address bit is 255. You can refer 

to the following sheet for more information.  

Address 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

ON 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

ON 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

ON 

ON 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

OFF 

ON 

OFF 

OFF 

OFF 

OFF 

OFF 

Summary of Contents for PTZ-3660SIR

Page 1: ...IR Intelligent Speed Dome User s Manual Version 1 0 0...

Page 2: ...Self diagnosis 2 1 2 13 Day Night Mode B W Color Mode 2 1 2 14 Auto Focus 2 1 2 15 Backlight Compensation 2 1 2 16 Pan Tilt and Zoom 2 1 2 17 3D Intelligent Location 3 1 2 18 Idle Status 3 1 2 19 Powe...

Page 3: ...nformation 14 4 3 4 3 4 3 4 3 Main Menu Main Menu Main Menu Main Menu 14 4 4 Menu Operation 15 4 4 1 System Information 15 4 4 2 Display Setting 16 4 4 3 Camera Setting 16 4 4 4 Function Setting 20 4...

Page 4: ...ds and Terminal Resistance Connection Methods and Terminal Resistance Connection Methods and Terminal Resistance 30 7 4 7 4 7 4 7 4 The Problem in Practical Use The Problem in Practical Use The Proble...

Page 5: ...eference tool for the operation of your system Here you can find information about this speed dome features and functions as well as a detailed menu tree Please keep it well for future reference Befor...

Page 6: ...nstallation Do not put object on the product 4 Environment This series product should be installed in a cool dry place away from direct sunlight inflammable explosive substances and etc The working te...

Page 7: ...ch dust please use the water to dilute the mild detergent first and then use it to clean the device Finally use the dry cloth to clean the device 6 About Accessories Always use all the accessories rec...

Page 8: ...2 F F F Feature eature eature eatures s s s This series speed dome has the following features 1 2 1 On Screen Menu This series product menu supports multiple languages display and switch It is easy fo...

Page 9: ...the keyboard joystick in the down position the dome rotates 180 degrees and repositions itself for uninterrupted viewing of any subjects that passes directly beneath the dome 1 2 12 Self diagnosis Th...

Page 10: ...order you can use menu to set dome idle status after specified duration The idle status includes turn to specified preset or go to scan tour or pattern function 1 2 19 Power up The speed dome execute...

Page 11: ...tight structure Elegant mechanical driver device Support 360 degrees continuous rotation no monitor blind spot 0 1 s rotation speed while maintain stable image 180 degrees tilt continuous monitor Buil...

Page 12: ...th lens Auto Rotation Tilt 92 auto rotates to pan 180 Auto Pan 0 360 continuously Manual Pan Motion Speed 0 1 200 S Preset Maximum Speed 60 240 s There are 16 level You can set from the menu Manual Ti...

Page 13: ...can not control the product 2 1 2 1 2 1 2 1 Protocol and Protocol and Protocol and Protocol and B B B Baud aud aud aud R R R Rate ate ate ate S S S Setup etup etup etup Please configure the following...

Page 14: ...se refer to the parity setup sheet for detailed information 6 7 Parity OFF OFF NONE ON OFF EVEN OFF ON ODD ON ON NONE 2 2 2 2 2 2 2 2 Set address dial switch Set address dial switch Set address dial s...

Page 15: ...8 5 ON OFF ON OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF 7 ON ON ON OFF OFF OFF OFF OFF 8 OFF OFF OFF ON OFF OFF OFF OFF 254 OFF ON ON ON ON ON ON ON 255 ON ON ON ON ON ON ON ON...

Page 16: ...nsmit video signal control signal and power connection Please connect the power cable to the power socket of the speed dome connect the RS485 cable to the RS485 port of the speed dome See Figure 3 1 a...

Page 17: ...IDEO GND Ground port OUT Video output port Power port connection interface is shown as in Figure 3 3 Figure 3 3 Name Function AC24V 24V power port Connect to the power cable EARTH Ground port AC24V 24...

Page 18: ...eyboard Connection This series dome supports keyboard operation You can use keyboard to control the dome and PTZ The display and control can work simultaneously One keyboard can control maximum 255 sp...

Page 19: ...12 protocol The most direct and easy way is to use current system to process video signal and add some control keyboards to control speed dome See Figure 3 8 Figure 3 8...

Page 20: ...ON OFF ON OFF ZOOM DISP OFF ON OFF INSIDE TEMP F OFF TITLE DISPLAY BACK EXIT DISPLAY SETTING SYSTEM INFORMATION CAMERA SETTING FUNCTION SETTING EXIT WB SETTING AUTO EXPOSURE SETTING DAY NIGHT SETTING...

Page 21: ...e PTZ software version When you are using the control keyboard or the matrix host to control the device please make sure the control parameter of the keyboard or the matrix host is the same with the s...

Page 22: ...cursor to INITIAL INFORMATION and then click confirm button to go to the third submenu ADDR INFORMATION Move the cursor to SITE INFORMATION and then click confirm button to go to the third submenu SET...

Page 23: ...title or not Please use the left right button on the keyboard or in the speed dome terminal menu to set You can go to Function Setup Preset section to set corresponding preset value and preset title A...

Page 24: ...from 1 to 8 The bigger the value the faster the speed Please use the left right button on the keyboard or in the speed dome terminal menu to set DIGITAL ZOOM There are two options on off Please use t...

Page 25: ...posure speed to capture the image and enhance the definition The value ranges from 1 to 16 The bigger the value the higher the exposure speed Please use the left right button on the keyboard or in the...

Page 26: ...ns IR auto auto black and white color Please use the left right button on the keyboard or in the speed dome terminal menu to set SENSITIVITY It is the threshold value when the system switches from the...

Page 27: ...AUTO CRUISE It is to set the cruise tour number and task Move the cursor to AUTO CRUISE and then click confirm button to go to the third submenu AUTO PATTERN It is to set the pattern number and etc Mo...

Page 28: ...enu For PELCO protocol user please refer to the following special functions Call preset Call preset 28 or preset 95 to go to dome menu Call preset 29 or preset 99 to go to scan Call preset 24 or prese...

Page 29: ...speed dome terminal menu to set CRUISE SETTING Move the cursor to cruise setting item and then click confirm button You can see the following interface Here you can add or remove the preset and set th...

Page 30: ...t An icon OK pops up in screen to prompt you system begins memory pattern PROGRAM STOP Here is to set pattern stop point After all the movement move the cursor to PROGRAM STOP and then click confirm b...

Page 31: ...Fourthly move the cursor to RESIZE and then click left and right key to adjust privacy zone direction and size Fifthly move the cursor to SAVE and then click confirm button to exit PRIVACY NO Here is...

Page 32: ...ome terminal menu to set System begins specified scan when idle status is on CRUISE NO The value ranges from 1 to 8 Please use the left right button on the keyboard or in the speed dome terminal menu...

Page 33: ...me boots up The option includes NONE AUTO SCAN PRESET PATTERN TOUR and etc Please use the left right button on the keyboard or in the speed dome terminal menu to set PARAMTER Here you can set the seri...

Page 34: ...ity manual NEAR LIGHT It is the medium and near light brightness FAR LIGHT It is the far light brightness IR LIGHT COMPENSATION It is the whole compensation level of the IR light 4 5 Dome Abnormal Phe...

Page 35: ...wer socket Mechanical malfunction Need electrical engineer help Self diagnosis is ok No video signal Power connection is too loose connect tightly Check the circuit connection Connect again Video swit...

Page 36: ...g steel tube under the land to implement cable layout and connects one point to the earth Open floor cable layout is forbidden In area of strong thunderstorm hit or near high sensitive voltage such as...

Page 37: ...tic interference There are too much devices connected to the RS485 bus And vice versa the max transmission distance shall become longer 7 3 7 3 7 3 7 3 Connection Connection Connection Connection Meth...

Page 38: ...7 5 7 5 7 5 RS485 Bus FAQ RS485 Bus FAQ RS485 Bus FAQ RS485 Bus FAQ Phenomenon Possible Reasons Solution Speed dome can run self diagnosis but I can not control it Host address baud rate and speed dom...

Page 39: ...ation of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ T11363 2006 standard X Indicates that the concentration of the hazardous substance...