ICRealtime HD-AVS Quick Start Manual Download Page 2

1A. OVERVIEW

This  series  PTZ  camera  utilizes  High  Definition  Advanced  Video 

System  (HD-AVS)  technology,  an  HD-over-coaxial  cable  video 

standard  that  allows  long-distance,  HD  transmission  of  video, 

audio, and control functions. The camera supports TVI, AHD and 

CVBS (SD) using the dip switch.

The camera supports  DC24V/2.5A ± 25%, and draws from: 9.6W 

to 22W. It also is IP66 and IK10 rated with TVS 6000V lightning 

protection;  surge  protection,  making  it  a  suitable  choice  for 

outdoor environments.

Note

:  Take  careful  steps  when  handling  the  camera.  See  figure 

1-1.

1B. Cable Interface

See Figure 1-2.

1.

FC Connector

2.

DC Power input

3.

24VAC input:  Red(+), Black(-), Yellow/Green (ground)

4.

RS485: Yellow (A+), Orange (B-)

5.

Video output

6.

Ethernet port (on some models)

7.

Audio IO: White- Input, Red-Output, Black-Ground

8.

Alarm  IO:  Blue:  Alarm  output  1,  Black:  Alarm  output  2,  Green:  Contact 

switch 1, Pink: Contact switch, Yellow-green: Grounding cable, Red: Alarm 

input  1,  Brown:  Alarm  input  2,  Grey:  Alarm  input  3,  Light  green:  Alarm 

input 4, Purple: Alarm input 5, White: Alarm input 6, Yellow-black: Alarm 

input 7 

Figure 1-2

          

                                                                                       

MARGIN

GUIDES

To see the guides to go:

View / Guides / Show 

Guides

2  

|  

www.icrealtime.com

Figure 1-1

Summary of Contents for HD-AVS

Page 1: ...ne by the qualified service engineers We are not liable for any problems caused by unauthorized modifications or attempted repair Environment This series network camera should be installed in a cool dry place away from direct sunlight inflammable explosive substances and etc Please keep it away from the electromagnetic radiation object and environment Please make sure the CCD CMOS component is out of...

Page 2: ...le choice for outdoor environments Note Take careful steps when handling the camera See figure 1 1 1B Cable Interface See Figure 1 2 1 FC Connector 2 DC Power input 3 24VAC input Red Black Yellow Green ground 4 RS485 Yellow A Orange B 5 Video output 6 Ethernet port on some models 7 Audio IO White Input Red Output Black Ground 8 Alarm IO Blue Alarm output 1 Black Alarm output 2 Green Contac switch 1...

Page 3: ...p See Figure 2 1 Step 2 For outdoor installation four rubber grommets are provided for the mounting screws to waterproof the base See Figure 2 2 Step 3 Remove the dome cover using the wrench provided Thread the cabling through the cable exit on the installation surface and install the mounting screws as shown in Figure 2 3 Step 4 Connect the necessary cabling to the camera See Figure 2 4 Figure 2 ...

Page 4: ...4 www icrealtime com Step 5 Replace and secure the dome cover as shown in Figure 2 5 Step 6 It is recommended to waterproof any outdoor cabling See Figure 2 6 Figure 2 5 Figure 2 6 ...

Page 5: ...u Camera PTZ Make sure the Channel the PTZ is occupying is set to AVS mode Step 1 Using a mouse and a local display right click on the live view and select PTZ control The PTZ menu will populate See Figure 3 1 Step 2 Click to open PTZ Control Panel then click to open OSD The Use the up and down buttons to select menu item and the left and right to change parameter values Click Enter to confirm See ...

Page 6: ...etting Preset Auto Pan Auto Scan Tour Pattern Idle Motion Auto Run Privacy Masking PTZ Speed Set Zero Power Up Menu Password Menu Idle Channel Title PTZ Auto Stop Warm Machine PTZ Correction Alarm Setting Alarm No Action Parameter Contact Relay Out Reset Delay IR Light Setting IR Sensitivity IR Light Ctrl Near Light Far Light IR Light Comp 3C Function Settings Presets These are positions the PTZ c...

Page 7: ...tern This a recorded set of movements that the PTZ will follow Pattern No You can select different scan numbers to modify Program Start This records the pattern movement Click Enter to start An OK will flash indicating the PTZ movements will now be recorded Move the PTZ as desired Program End Select this option after you have finished recording your pattern Call Starts the recorded pattern movement ...

Page 8: ... the speed dome in an outdoor environment The signal transmission cable and high voltage device or high voltage cable should be at least 50 meters apart If possible route cables through a properly grounded and shielded underground conduit In areas of strong lightning occurrence or near high sensitive voltage such as near high voltage transformer substation it is required to install additional a hi...

Page 9: ...9 www icrealtime com Figure 5 1 Figure 5 2 4B LIGHTNING PROOF AND SURGE PROTECTION Continued ...