Flowrate Alarm
Set
Enter No.
,
Leave No.
, and
Stranded No.
The alarm is triggered
when the configured value is reached.
Regional People
Number Statistics
Alarm
Set the number of people in the people counting region. When the
people count reaches the threshold or the stay duration exceeds
the configured value, the alarm is triggered.
When you set inside number to be 0, and select the type to be
≥
Threshold
, the system will not perform the alarm linkage.
Inside Number
Type
Stranding Alarm
If enabled, set the stranding time. When the stay duration of the
people within the area exceeds the configured value, an event
will be created.
Stranding Time
Sensitivity
Set the alarm-triggered sensitivity. The higher the sensitivity, the
easier the alarm will be triggered.
Max Height
Set the maximum height of the people in the detection area. The
unit is in centimeters, and the range is 0–300.
Min Height
Set the minimum height of the people in the detection area. The
unit is in centimeters, and the range is 0–200.
Result
Step 6 Set arming periods and alarm linkage actions. For details, see "5.1.1 Alarm Linkage".
Step 7 Click
Save
.
To view alarm information on the
Alarm
tab, subscribe relevant alarm event. For details, see "5.1.2
Queuing
This function counts people queued in the detection area. When the queue number exceeds the
configured number or the queue time exceeds the configured time, the system will create an event.
Prerequisites
You will first need to configure
People Counting
.
Procedure
Step 1
Select
Setting
>
Event
>
Queuing
.
Figure 5-68 Queuing
165