ICP TSTAT0712 Installation Instructions Manual Download Page 9

Sample Wiring Diagrams

Gas or Electric Heat

Page 9

4 Wire, 1 Stage Cooling, 1 Stage Heat-Heat Pump with O reversing valve.

Residential Heat Pumps, split systems & package units, with no auxiliary heat.

FAN

POWER

G

R

COMPRESSOR

Y

W

Y
B

O
G

R

4 Conductor 18 gauge 
unshielded cable from the 
thermostat to the equipment.

REVERSING VALVE

O

INSTALLATION INSTRUCTIONS

C

Common wire optional

*

Common wire is optional in all installations.  If a common wire is not used the 
thermostat must be powered by the two AA Alkaline batteries (page 14).  These 
batteries must be replaced each year or when the Low Battery indicator is 
displayed (page 3, 6).

*

Summary of Contents for TSTAT0712

Page 1: ...n 1 stage heat cool gas electric or heat pump 1 STAGE HEAT COOL THERMOSTAT SINGLE STAGE HEAT PUMP COMPATIBLE Does not control auxiliary heat Use with most Air Conditioning Heating Systems including 1...

Page 2: ...Contents Page Page 2 Remove Old Thermostat Safety Warnings Preparation Installation Battery Replacement Wire Connections Jumper Configuration Test Operation Troubleshooting Warranty INSTALLATION INSTR...

Page 3: ...are not required When is displayed the batteries must be replaced immediately The manufacturer cannot be liable for improper operation of the thermostat if the batteries are not immediately replaced...

Page 4: ...sidential systems have a separate breaker for disconnecting power to the furnace Proper installation of the thermostat will be accomplished by following these step by step instructions If you are unsu...

Page 5: ...rk them with the letter of the terminal for easy reconnection to the new thermostat Keep the old thermostat for reference purposes until your new thermostat is functioning properly Page 5 INSTALLATION...

Page 6: ...ocedure in the other screw driver slot Separate the housing halves by pulling the top forward until the pins release and then lift the bottom out To pull the housing apart insert a small blade screw d...

Page 7: ...G O Rev Valve Energize to Cool O A label is provided on the backplate that prevents drafts originating inside the wall from entering the thermostat These drafts left unchecked may cause incorrect room...

Page 8: ...ooling 1 Stage Gas Heat Residential Gas or Electric Heat Electric Cool split systems package units INSTALLATION INSTRUCTIONS C Common wire optional Common wire is optional in all installations If a co...

Page 9: ...MPRESSOR Y W Y B O G R 4 Conductor 18 gauge unshielded cable from the thermostat to the equipment REVERSING VALVE O INSTALLATION INSTRUCTIONS C Common wire optional Common wire is optional in all inst...

Page 10: ...OMPRESSOR Y W Y B O G R 4 Conductor 18 gauge unshielded cable from the thermostat to the equipment REVERSING VALVE B INSTALLATION INSTRUCTIONS C Common wire optional Common wire is optional in all ins...

Page 11: ...ire 1 Stage Heat Residential Gas or Electric Heat units with a separately controlled fan INSTALLATION INSTRUCTIONS C Common wire optional Common wire is optional in all installations If a common wire...

Page 12: ...nt 2 Wire 1 Stage Gas Heat Residential Gas or Millivolt units INSTALLATION INSTRUCTIONS C Common wire optional Common wire is optional in all installations If a common wire is not used the thermostat...

Page 13: ...quipment 3 Wire 1 Stage Cooling Residential Electric Cool units INSTALLATION INSTRUCTIONS C Common wire optional Common wire is optional in all installations If a common wire is not used the thermosta...

Page 14: ...e GAS position If the HVAC unit is a residential Heat Pump then jumper should be set to HP For all other applications this jumper should remain set to the GAS position IF THERMOSTAT IS NOT SYSTEM POWE...

Page 15: ...emperature is 10 degrees below room temperature The HVAC unit should energize in the cooling mode Turn on the power to the Heating Air Conditioning system Adjust the Slide Switch until it is located u...

Page 16: ...the thermostat Install a common wire from the 24v transformer powering the thermostat SYMPTOM The slide switches on the thermostat are very difficult to move CAUSE The backplate of the thermostat is d...

Page 17: ...setpoint and to correct the Mode Switch position or replace the batteries SYMPTOM The heating does not attempt to turn on CAUSE The heating setpoint is set too low or the Mode Switch is not set for H...

Page 18: ...ST be programmed for any time AFTER the 6 30am Morning Start Time Also if the Day Start time is set for 10 30am then the Evening Start Time MUST be programmed for any time AFTER the 10 30am Day Start...

Page 19: ...THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WAR...

Reviews: