ICP TSTAT0710 Installation Instructions Manual Download Page 3

Proper installation of the thermostat  will be
accomplished by following these step
by step instructions.  If you are unsure
about any of these steps, call a qualified
technician for assistance.

Assemble tools 

Make sure your Heater/Air Conditioner
is working properly before beginning
installation of the thermostat.

Carefully unpack the thermostat.
Save the screws, bracket, and 
instructions.

STEP #1

PREPARATION

Page 2

Turn off the power to the Heating/Air
Conditioning system at the main fuse
panel.  Most residential systems have 
a separate breaker for disconnecting
power to the furnace.

Flat Blade
Screwdriver

Wire cutter
& Stripper

70

C

OOL

o

Am

 6:03

70

Su

Mode

Cooler

Warmer

70

C

OOL

o

Am

 6:03

70

Su

Mode

Cooler

Warmer

70

C

OOL

o

Am

 6:03

70

Su

Mode

Cooler

Warmer

70

C

OOL

o

Am

 6:03

70

Su

Mode

Cooler

Warmer

70

C

OOL

o

Am

 6:03

70

Su

Mode

Cooler

Warmer

Summary of Contents for TSTAT0710

Page 1: ...DIGITAL THERMOSTAT P N TSTAT0710 Installation Instructions MULTI STAGE PROGRAMMABLE HEAT PUMP HEAT COOL International Comfort Products 2003 70 COOL o Am 6 03 70 Su Mode Cooler Warmer...

Page 2: ...THE HEATER AIR CONDITIONER BEFORE REMOVING THE OLD THERMOSTAT AND INSTALLING THE NEW THERMOSTAT WARNING 2 3 4 5 8 10 9 This device complies with Part 15 of the FCC rules Operation is subject to the fo...

Page 3: ...y unpack the thermostat Save the screws bracket and instructions STEP 1 PREPARATION Page 2 Turn off the power to the Heating Air Conditioning system at the main fuse panel Most residential systems hav...

Page 4: ...e wires as you disconnect them and mark them with the letter of the terminal for easy reconnection to the new thermostat STEP 2 REMOVE REPLACE OLD THERMOSTAT Page 3 Keep the old thermostat for referen...

Page 5: ...a Heat Pump Wire from the old thermostat terminal marked Function Install on the new thermostat connector marked G or F Fan G Y1 Y or C Cooling Y1 W1 W or H Heating W1 O B W1 O B Power Rh R M Vr A R...

Page 6: ...an relay compressor relay 1st stage heat circuit 5 Wire 1 Stage Cooling 1 Stage Gas Heat 4 Wire 1 Stage Cooling 1 Stage Gas Heat Residential Gas or Electric Heat Electric Cool split systems package un...

Page 7: ...Y1 Y2 W1 W2 O 24 vac common 24 vac return fan relay compressor relay 1st stage heat circuit 2nd stage heat circuit Residential 2 Stage Cooling with Gas or Electric Heat Residential commercial 1 Stage...

Page 8: ...Commercial Gas or Electric Heat Electric Cool split systems package units including Commercial Heat Pumps No auxiliary heat residential Heat Pumps split systems package units 7 Wire 2 Stage Cooling 2...

Page 9: ...very thermostat is calibrated before it leaves the factory Under normal circumstances there will never be a need to recalibrate the thermostat again To accommodate special needs the thermostat may be...

Page 10: ...ees below room temperature The air conditioner should turn on NOTE Most equipment has a time delay of 5 minutes between cool cycles This feature is defeatable on the thermostat Consult the Owner s Man...

Page 11: ...he compressor timer lockout may prevent the air conditioner from turning on for a period of time REMEDY Consult the Owner s Manual in the Setup section to defeat the cycles per hour and compressor tim...

Page 12: ...e Owner s Manual in the Setup section to lower the cooling setpoint limit SYMPTOM The heating does not attempt to turn on CAUSE The heating setpoint is set too low REMEDY Consult the Owner s Manual in...

Page 13: ...alling for cooling both the heat and cool come on CAUSE The Advanced Setup is configured to control a heat pump and the hvac the thermostat is controlling is a conventional non heat pump system REMEDY...