Air Cleaner 

- Cumulative Run Time default is 0 hours (OFF) and Calendar 

Time is OFF.  Values can range from 400-3600 hours for 
Cumulative Run Time (in 100 hour increments), or Calendar Time 
can be set to OFF, or 3-24 months (in 3 month increments). 

 
INPUT DEALER INFO 

Contractors are able to input Brand Name, Model Number, Contractor 
Name, and Contractor Phone number into these screens.  This way, the 
owner could give this information to the contractor so that he would know 
what system the owner has prior to the service visit.   
 

 

            

 

INPUT DEALER INFO 

BRAND NAME
MODEL NUMBER
CONTRACTOR NAME
CONTRACTOR PHONE
SAVE

SELECT OPTION 

∇∆

PREVIOUS

BRAND NAME

             

 

DEALER INFO

BRAND NAME 

USE 

∇∆

TO SCROLL

THRU CHARACTERS

A

_____________________________

CHANGE LETTER 

∇∆

PREVIOUS

A

 

 

1.

 

Scroll to the info you want to enter and press the center button 

2.

 

Enter the information by scroll through the characters using the up & 
down arrows 

▲▼

.  Once the character you want is set, press the right 

arrow 

 to move to the next space and begin entering another character.  

3.

 

Once you’ve completed filling out the field, press the center button 

 to 

save the entry and return to the INPUT DEALER INFO screen.  Repeat 
this process for all fields you want saved.   

4.

 

Once all fields have been entered, scroll to SAVE and press the center 
button 

 
FAN WITH HEAT OPTION 

    Options are ON or OFF.  This selection determines whether G (fan) output 
is to be ON or OFF when W (auxiliary heat) output is ON in dual fuel 
applications.  
 

 
HUMIDIFY/DEHUMIDIFY OPTION 
    If your system is setup with a humidifier, or a dehumidification option, select 
the appropriate setting.   
 
HUMIDIFY ONLY 
DEHUMIDIFY ONLY 
NONE 
 
To adjust the Set Point for Humidification or Dehumidification, Select the RH 
from the Main menu.  The values can be selected and adjusted from that screen. 
NOTE: If you have an outdoor sensor attached to the thermostat, the 
Humidification setting is adjusted automatically based on the outdoor 
temperature. 

 
 

REVERSING VALVE OPTION 
    Option of the reversing valve (O/B output) being on when in cooling or 

heating.  Default is COOLING. 

 

RESTORE DEFAULTS 
    This will allow you to revert to the factory default settings.  The 

configuration settings will not rest when this option is used.   

 

 

 

 

                                                                                                      

 

Review PROGRAM and HOLD sections to know effects of changing the set point 

7