Technical data
iMAT 31IFBI-24VDC
7
Pos : 22 /Beko T ec hnis che D okumentati on/Übersc hriften/1/T ec hni sche D aten @ 0\mod_1184329570967_15098.doc x @ 15131 @ 1 @ 1
5
Technical data
Pos : 23 /Beko T ec hnis che D okumentati on/Tec hnische D aten/BEKOM AT/T ec hn. D aten BM 3xU + UC + GOST (o.Leistg.) @ 5\mod_1358843578945_15098.doc x @ 30477 @ @ 1
min./max. operating pressure
(see type plate)
0,8...16 bar (12...230 psi)
or
1,2...16 bar (17...230 psi)
min./max. temperature
(see type plate)
+1...+60 °C (+34...+140 °F)
or
+1...+70 °C (+34...+158 °F)
Condensate inflow
G ½ internal
max. screw-in depth 13,5 mm (½")
Condensate outflow
G ¼ Ø 8 ... 10 mm hose connector
Condensate
oil-contam oil-free
Housing
alu plastic, glass fibre-reinforced
Weight (empty)
0,6 kg (1.3 lbs)
This product has been tested to the requirements of CAN/CSA-C22.2 No. 61010-1-12, third edition,
including a later version of the same standard incorporating the same level of testing requirements.
Pos : 24 /---- Seitenumbr uch ---- @ 0\mod_1157028099015_0.doc x @ 15320 @ @ 1
Pos : 25 /Beko T ec hnis che D okumentati on/Übersc hriften/1/Elektrische D aten @ 0\mod_1183638451371_15098.doc x @ 15115 @ 1 @ 1
6
Electrical data
Pos : 26 /Beko T ec hnis che D okumentati on/El ektrisc he Daten/BEKOM AT/Elektrische D aten BM IF @ 1\mod_1294308188293_15098.doc x @ 20705 @ @ 1
Supply voltage
(see type plate)
24 VDC ± 10 % from a power supply unit with safe (mains) separation
Power consumption
P < 2 W
Fusing
device has an internal
self-resetting fuse 0.3 A
Recommended
cable-jacket diameter
Ø 5,0…10 mm (0,20“…0,39“)
Recommended
wire cross-section
0,25...1,5 mm² (AWG 16...24)
Recommended
stripping of cable jacket
~ 50 mm (~ 1.97")
Recommended
length of the wire end tube
~ 8 mm (~ 0.31 inch)
Protection class
IP 67