Technical description
iDRY iRDP CT 20-500
19
8.12.4 Indication of a Service Warning
A service warning is an exceptional event and requires the attention of the operator/service technician. The dryer will
not be stopped.
When a service warning is active, the
Led flashes.
When a service warning is no longer active but not reset yet (so it has been stored)
Led is continuously on.
In both cases the display shows the dew point temperature and the service warnings which are active or which are no
longer active but not yet reset.
Service warnings are NOT automatically reset.
To
RESET
the service warning,
the
Led must be continuously on (not flashing), keep pressed simultaneously
Set
+
buttons for three seconds. Only the stored service warning will be reset. Service warnings which
are still active continue to be indicated by the
Led flashing.
NOTE: the operator/service technician must check the dryer and eliminate the problem that caused the service
warning.
Service warning
Description
HdP – High dew point: dew point too high, higher than the adjusted HdS value
LdP – Low dew point: dew point too low
Setting T1< -1°C (30°F) delay five minutes / reset T1> -0.5°C (31°F)
SrV - Service: maintenance service time expired SrV
8.12.5 Indication of an Alarm
An alarm is an exceptional event which, to avert damage from to the machine and the operator, always leads to the
dryer stop.
When an alarm is active, the
LED flashes.
When an alarm is no longer active but not reset yet (so it has been stored)
Led is continuously on (in any case,
the dryer remains OFF).
In both cases the display shows
and the alarms which are active or which are no longer active but not yet reset.
Alarms are NOT automatically reset.
To
RESET
the alarm,
the
Led must be continuously on (not flashing), keep pressed simultaneously
Set
+
buttons for three seconds. Only the stored alarm will be reset. Alarms which are still active continue to be
indicated by the
Led flashing.
The dryer will start automatically subsequent to the reset of the alarms.
NOTE: the operator/service technician must check the dryer and eliminate the problem that caused the alarm.
Alarm Description
LP – Low pressure: the refrigerant low-pressure switch LPS has tripped.
Hdt – High outlet temperature: compressor outlet temperature outside the safety limit
Setting T2> 110°C (230°F) delay one minute / reset T2< 90°C (194°F)
ICE - ICE / Icing: Temperature in the exchanger (probe T1) is too low and leads to icing
of the condensate.
Setting T1< -2°C (28°F) delay one minute / reset T1> 0°C (32°F)
toC – Too many Cycles : compressor has been cycled On/OFF unusually too often
(stopped more than 5 times before reaching its minimum ON time)
PF1 – Probe 1 failure: failure probe T1
PF2 – Probe 2 failure: failure probe T2
Summary of Contents for iDRY iRDP CT 30
Page 29: ...Technical data iDRY iRDP CT 20 500 29 11 2 Technical data iDRY iRDP CT 20 500 2 1 230 60...
Page 38: ...Maintenance troubleshooting spare parts and dismantling 38 iDRY iRDP CT 20 500...
Page 39: ...Maintenance troubleshooting spare parts and dismantling iDRY iRDP CT 20 500 39...
Page 42: ...Appendices 42 iDRY iRDP CT 20 500 13 1 2 Dryer dimensions iDRY iRDP CT 75...
Page 43: ...Appendices iDRY iRDP CT 20 500 43 13 1 3 Dryer dimensions iDRY iRDP CT 100 150...
Page 44: ...Appendices 44 iDRY iRDP CT 20 500 13 1 4 Dryer dimensions iDRY iRDP CT 200 250...
Page 45: ...Appendices iDRY iRDP CT 20 500 45 13 1 5 Dryer dimensions iDRY iRDP CT 300 350...
Page 46: ...Appendices 46 iDRY iRDP CT 20 500 13 1 6 Dryer dimensions iDRY iRDP CT 400 500...
Page 47: ...Appendices iDRY iRDP CT 20 500 47 13 1 7 Dryer dimensions iDRY iRDP CT 200 250 3phase...
Page 48: ...Appendices 48 iDRY iRDP CT 20 500 13 1 8 Dryer dimensions iDRY iRDP CT 300 350 3phase...
Page 49: ...Appendices iDRY iRDP CT 20 500 49 13 1 9 Dryer dimensions iDRY iRDP CT 400 500 3phase...
Page 51: ...Appendices iDRY iRDP CT 20 500 51 13 2 2 Exploded diagram iDRY iRDP CT 20 30...
Page 52: ...Appendices 52 iDRY iRDP CT 20 500 13 2 3 Exploded diagram iDRY iRDP CT 50...
Page 53: ...Appendices iDRY iRDP CT 20 500 53 13 2 4 Exploded diagram iDRY iRDP CT 75...
Page 54: ...Appendices 54 iDRY iRDP CT 20 500 13 2 5 Exploded diagram iDRY iRDP CT 100...
Page 55: ...Appendices iDRY iRDP CT 20 500 55 13 2 6 Exploded diagram iDRY iRDP CT 125 150...
Page 56: ...Appendices 56 iDRY iRDP CT 20 500 13 2 7 Exploded diagram iDRY iRDP CT 200 250...
Page 57: ...Appendices iDRY iRDP CT 20 500 57 13 2 8 Exploded diagram iDRY iRDP CT 300 350...
Page 58: ...Appendices 58 iDRY iRDP CT 20 500 13 2 9 Exploded diagram iDRY iRDP CT 400 500...
Page 59: ...Appendices iDRY iRDP CT 20 500 59 13 2 10 Exploded diagram iDRY iRDP CT 200 250 3phase...
Page 60: ...Appendices 60 iDRY iRDP CT 20 500 13 2 11 Exploded diagram iDRY iRDP CT 300 350 3phase...
Page 61: ...Appendices iDRY iRDP CT 20 500 61 13 2 12 Exploded diagram iDRY iRDP CT 400 500 3phase...