Preparation 

1) 

Turn the switch to “Init” 

2) 

Connect tZT-P4C4 module. 

i. 

Open DCON Utility and use ZT-2000 Coordinator connect 
Default Parameter

 

Protocol 

DCON 

CheckSum  Disable 
PAN ID 

0x1234 

Node ID 

0x01 

RF Channel  0x0E 
RF Power 

0x07 

ii. 

Use RS-232 

3) 

Power supply range

+10 ~ +30 VDC 

4  

Communication Test 

As the ZigBee network is controlled by the ZigBee coordinator, the 

ZT-2550/ZT-2570 (ZigBee coordinator) must be configured first. Please 
refer to documents shown below for full details of how to configure these 
devices. 

Once configuration of the ZigBee coordinator has been completed. 

Set the ”Pan ID” and the “RF Channel” values for the tZT-P4C4 to the 
same values as the network, and then reboot the device. The module 
will automatically start to function on the ZigBee network using the 
default protocol. 

 

  Documents 

http://ftp.icpdas.com.tw/pub/cd/usbcd/napdos/zigbee/zt_series/document/zt-255x/

 

http://ftp.icpdas.com.tw/pub/cd/usbcd/napdos/zigbee/zt_series/document/zt-257x/

 

 

  Configuration Utility 

(Used to configure ZT-2000 I/O device Coordinator) 

http://ftp.icpdas.com.tw/pub/cd/usbcd/napdos/zigbee/zt_series/utility/

 

Summary of Contents for tZT-P4C4

Page 1: ...in the same ZigBee network Setting Range 0x0000 0x3FFF 2 Address Node ID distinguish identity of a specific the ZigBee module and must be unique for each device connected the same ZigBee network Setting Range 0x01 0xFF 3 RF Channel indicates the radio frequency channel and must be set to the same value as other modules on the same ZigBee network Channel 0x00 0x01 0x0F Frequency MHz 2405 2410 2480 ...

Page 2: ...e refer to documents shown below for full details of how to configure these devices Once configuration of the ZigBee coordinator has been completed Set the Pan ID and the RF Channel values for the tZT P4C4 to the same values as the network and then reboot the device The module will automatically start to function on the ZigBee network using the default protocol Documents http ftp icpdas com tw pub...

Page 3: ...sed to simulate DCON Modbus communication This software can also be used to verify the device settings and ZigBee I O functions The DCON Utility can be download from http ftp icpdas com pub cd 8000cd napdos driver dcon_utility Simulate I O channel operating via using DCON Utility 1 Launch DCON Utility and select the correct COM Port settings to connect the ZigBee Coordinator ZT 2550 ZT 2570 2 Clic...

Page 4: ...following message will be displayed 2 LED Indicator Status LED Indicator Status Introduction ZBNet Green LED ZigBee Coordinator Master Steady Lit ZigBee Net is set up correctly Blinking to Steady Lit Already have same ZigBee network or rejoin ZigBee network ZigBee Router Slave Steady Lit The Signal is Strong Blinking 500ms The Signal is Available Blinking 1s The Signal is Weak Blinking 2s The Sign...