background image

 

Copyright © 2009 ICP DAS Co., Ltd. All Rights Reserved. 

 E-mail: [email protected] 

tM

-R

5

 Q

u

ic

k

 S

ta

rt

 

7

 

 

 

 

 

 

Double-click the DCON Utility 

shortcut on your desktop. 

 

 

 

 

 

 

Click the “COM Port” option from the menu and a dialog box will be displayed that will allow 

you to set the communication parameters as described in the table below. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Communication   

parameter 

INIT Mode   

 

Address 

00 

Baud Rate 

9600 

Protocol 

DCON 

Checksum 

Disabled 

Parity 

N,8,1 

Step 1: Run the DCON Utility 

Step 2: Use the COM1 port to communicate with the tM-Series 

All manuals and user guides at all-guides.com

Summary of Contents for tM-R5

Page 1: ...automation solution for remote monitoring and control applications This Quick Start will provide information needed to get started with the tM R5 Please also consult the User Manual for detailed info...

Page 2: ...om tM R5 Quick Start 2 1 Understanding the Hardware Specifications and Wiring Diagrams Before installing the hardware you should have a basic understanding of hardware specification and the wiring dia...

Page 3: ...Copyright 2009 ICP DAS Co Ltd All Rights Reserved E mail service icpdas com tM R5 Quick Start 3 I O Specifications Wire Connection All manuals and user guides at all guides com...

Page 4: ...DAS Co Ltd All Rights Reserved E mail service icpdas com tM R5 Quick Start 4 Pin Assignment Make sure the switch placed in the Init position 2 Booting the tM R5 in Init Mode All manuals and user guide...

Page 5: ...Power Supply The tM Series series is equipped with an RS 485 port for connection to a 232 USB converter to PC Connect to the PC using an RS 485 Converter Connect to PC using a USB Converter I 7520 Pow...

Page 6: ...icpdas com pub cd 8000cd napdos driver dcon_utility After the installation has been completed there will be a new shortcut to the DCON Utility on the desktop The tM Series is an I O module based on th...

Page 7: ...from the menu and a dialog box will be displayed that will allow you to set the communication parameters as described in the table below Communication parameter INIT Mode Address 00 Baud Rate 9600 Pr...

Page 8: ...to search for the tM Series module After the tM Series module is displayed in the list click Stop Search button After clicking on the name of the module in the list a dialog box will be displayed Sta...

Page 9: ...e INIT switch is placed in the RUN position 7 Starting the Module Operation After rebooting the tM Series module search for the module to make sure the settings have been changed You can double click...

Page 10: ...0073 10077 High latched values of DO R 10105 10109 Low latched values of DO R 00001 00005 Digital output value of channel 0 4 R W 00129 00133 Safe value of digital output channel 0 4 R W 00161 00165 P...