PET-AR400 User Manual
V1.0.0
P.13
Mechanical
Dimensions (W x L x H)
76 mm x 120 mm x 38 mm
Installation
DIN-Rail or Wall Mounting
Enclosures
Metal
Environment
Operating Temperature
-25 ~ +75 °C
Storage Temperature
-30 ~ +80 °C
Humidity
10 ~ 90 % RH, Non-condensing
1.2.2.
I/O Specification
IEPE Input
Channels
4 Differential (Simultaneously)
Range
+/-10 V
Resolution
24-bit
Accuracy
+/- 0.02 % of FSR @+/-10V
Sampling Rate
32 kHz @ 3/4 channels
64 kHz @ 2 channels
128 kHz @ 1 channel
Input Impedance
2M Ohm
FIFO Size
1 k bytes, 256 Samples
Trigger Mode
Software, Analog Threshold Trigger
Excitation Current
4 mA (IEPE compliance
:
24 V)
Input Common Mode Range
+/-10 V
Input coupling
AC coupling
Cutoff frequency
0.16 Hz
Input Bandwidth
12.8 kHz (-0.1 db) @ 1/2/3 channel(s)
6.4 kHz (-0.1 db) @ 4 channels
Connectors
BNC (female)