PEX-CAN200i-D/T
Table 2.4 Jumper Selections
Jumper Description
Status
Enable Disable
Port 1 terminator
resister(120
Ω
) selection
1 2 3
1 2 3
JP2
Port 2 terminator
resister(120
Ω
) selection
JP3
1 2 3
1 2 3
PCM-CAN100 and PCM-CAN200
Table 2.5 shows the appropriate switch setting and signals used for each
module in the stack.
Table 2.5 Rotary Switch Settings
Switch Position
Module Slot
CLK
ID Select
INT
0 or 4 or 8
1
CLK0
IDSEL0
INTA
1 or 5 or 9
2
CLK1
IDSEL1
INTB
2 or 6
3
CLK2
IDSEL2
INTC
3 or 7
4
CLK3
IDSEL3
INTD
Table 2.6 Jumper Selections
Jumper Description
Status
Enable Disable
JP3
Port 1 terminator
resister(120
Ω
) selection
3 2 1
3 2 1
JP4
3 2 1
3 2 1
Port 2 terminator
resister(120
Ω
) selection
(only for
PCM-CAN200)
PISO-CAN/PEX-CAN/PCM-CAN Series User’s Manual (v2.6 Dec/2013) -------