background image

 

PCI-1002, PEX-1002 L/H Series Quick Start Guide

 

ICP DAS CO., LTD. 

WebSite: http:// www.icpdas.com.tw      E-Mail: [email protected] , [email protected] 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 

The package includes the following items: 

 

 

One PCI/PEX-1002 series board as follows: 

 

PCI-1002LU, PCI-1002HU 

 

PEX-1002L, PEX-1002H 

 

One Software Utility CD (V5.2 or later) 

 

One Quick Start Guide (This Document) 

 

One CA-4002 D-Sub connector 

 

 

 
 

 

 

Step 1:

 

Setup the Windows driver. The driver is located at:   

 

 

The UniDAQ driver supports 32-/64-bit Windows 2K/XP/2003/Vista/7/8; it 
is recommended to install this driver for new user: 

CD: \NAPDOS\PCI\UniDAQ\DLL\Driver 

http://ftp.icpdas.com/pub/cd/iocard/pci/napdos/pci/unidaq/dll/driver/

 

 

 

   

For PCI-1002 LU/HU 

PEX-1002 L/H 

What’s in the shipping package?

 

English/ Jun. 2013/ Version 1.0

 

 

Installing Windows Driver

 

Summary of Contents for PCI-1002 LU

Page 1: ...Utility CD V5 2 or later One Quick Start Guide This Document One CA 4002 D Sub connector Step 1 Setup the Windows driver The driver is located at The UniDAQ driver supports 32 64 bit Windows 2K XP 200...

Page 2: ...on Step 4 Select the installed folder the default path is C ICPDAS UniDAQ confirm and click the Next button Step 5 Check your DAQ Card on list then click the Next button Step 6 Click the Next button o...

Page 3: ...Setting Card ID 1 ID0 2 ID1 3 ID2 4 ID3 0 ON ON ON ON 1 OFF ON ON ON 2 ON OFF ON ON 0xD OFF ON OFF OFF 0xE ON OFF OFF OFF 0xF OFF OFF OFF OFF Step 1 Shut down and power off your computer Step 2 Remov...

Page 4: ...PCI 1002 PEX 1002 L H Series Quick Start Guide ICP DAS CO LTD 4 WebSite http www icpdas com tw E Mail service icpdas com service icpdas gmail com Pin Assignments...

Page 5: ...pdas com service icpdas gmail com DIO Test Wiring 1 Use CA 2002 optional to connect the CON1 with CON2 Analog Input Test Wiring 2 Prepare for device DN 37 optional Wiring terminal board Provide a stab...

Page 6: ...e the signals as follows Connect the AI 0 Pin01 to signal positive Connect the A GND Pin17 to signal negative 5 Execute the UniDAQ Utility Program This program UniDAQ Utility will be placed in the def...

Page 7: ...as com tw E Mail service icpdas com service icpdas gmail com 6 Get DIO function test result Select the Port 0 8 The corresponding D I becomes red for channel 0 2 4 6 of D O is ON 9 Click Digital Input...

Page 8: ...002 html DN 37 CA 3710 and CA 2002 page optional http www icpdas com products DAQ screw_terminal dn_37 htm http www icpdas com products Accessories cable cable_selection htm Documentation and Software...

Reviews: