Web  Management  User  Manual 

Industrial  Managed  Ethernet  Switch 

Version 1.0 

This  document  applied  to  models  of   

  MSM-508,MSM-508FC/FCS/FT 

C o p yr i g h t

©

  I C P   D A S   C o . ,   L t d . ,   A l l   R i g h t s   R e s e r ve d .  

 

Summary of Contents for MSM-508

Page 1: ...April 29 2008 TM Web Management User Manual Industrial Managed Ethernet Switch Version 1 0 This document applied to models of MSM 508 MSM 508FC FCS FT Copyright ICP DAS Co Ltd All Rights Reserved...

Page 2: ...dundant Setting 8 Recovery Time Setting 9 4 Port configuration 11 Mirror 11 Trunking 12 Port Status 12 Cable Checking 13 5 Relay Alarm 14 Relay Output 14 6 Email Alarm 15 Alarm Event setting 15 Email...

Page 3: ...April 29 2008 10 Authentication 22 Account 22 Accessible IP 23 Default Setting 24 Reboot Setting 24...

Page 4: ...guide you how to configure ICPDAS Managed Switch through web browser Web Management support two levels of authentication administrator level and user level The administrator level allows you to monit...

Page 5: ...you can refer RS 232 Console Operation manual for more detail Following we will show you how to connect to the Web Management step by step STEP 1 Execute web browser application ex Mozilla Netscape I...

Page 6: ...thernet Layer 2 Managed Switch Web Management Manual April 29 2008 3 For login to Web Management your browser must support HTTP authentication It allows a web browser to provide credentials when makin...

Page 7: ...formation Use to memo the extra description of the Switch Module 16 characters max Web Server TCP Port Specify the connection port of the Web Server Default setting is 80 Date Time Setting This functi...

Page 8: ...bit numeric address consisted as four numbers separated by three dots The range of each number is from 0 to 255 Managed Switch doesn t support dynamic IP assignment you have to specify the IP address...

Page 9: ...identifies the device of MAC layer network The standard IEEE 802 format for human readable is six groups of two hexadecimal digits each digit separated by a dash or colon The factory default value is...

Page 10: ...setting is Baud Rate 115200 Data Bit 8 Parity Check 0 None Stop Bit 1 COM2 is the RS485 standard use for Modbus communication Factory default setting is Baud Rate 115200 Data Bit 8 Parity Check 0 None...

Page 11: ...To manage the Managed Switch for use in redundant network topology following configuration options are available Redundant Setting This function enables you to configure the Switch operation modes Rin...

Page 12: ...le Hello Time Forward Time and Max age Time automatically An adequate recovery time is depended on how many Managed Switch are consisted in the Ring coupling the more Managed Switch that you have the...

Page 13: ...es from pre forwarding state to forward state Factory default is 10000ms the variable is from 4000ms to 30000ms 30 sec Setting is only available on STP Mode Maxage Time STP Protocol Max age time is th...

Page 14: ...Specify the ports will be monitored There are two type of monitoring options Egress Monitor the packets which are sent out the switch port Egress Ingress Monitor the packets both entering into and bei...

Page 15: ...hysical ports into a single logical channel It can increase the link speed and provide the better redundancy availability Supported groups depend on the total number of switch ports on the equipment 5...

Page 16: ...OFF Link is down Cable Checking This function provides a useful tool to detect the quality of cables Tick the checkbox of Ports and click Start Check button after a moment waiting system will report t...

Page 17: ...you to configure the relay warnings of Power Link Lose and Communication Lose System Relay Alarm When alarm occurred the relay output on the Terminal Block is activated and System Relay Alarm is turn...

Page 18: ...t Power1 ON The status of power1 from OFF turns to ON Power2 ON The status of power2 from OFF turns to ON Power1 OFF The status of power1 from ON turns to OFF Power2 OFF The status of power2 from ON t...

Page 19: ...ime between 1 to 99 hour s and system will sending the system report by email every the specified hour s Before active email sending you have to finish following settings Mail Server IP IP address of...

Page 20: ...Manual April 29 2008 17 Email Record Switch Management can keep the sending date time and status of each warning emails But only the latest 50 sending records will be saved User can click the Clean Re...

Page 21: ...it s isolated from the other network logically A VLAN provides higher communication security and makes you to limit traffic flooding easily VLAN Mode Port Based VLAN The frames which arrive at specifi...

Page 22: ...ch Management supports the different VID setting up to 64 in max If the rules of the setting have conflict the smaller number of VID has the higher priority VID Specify the VID number the valid value...

Page 23: ...me QoS Mode There are two options supported to classify egress frames 8 4 2 1 Weight Fair queuing scheme 8 4 2 1 weighting is mapped to 4 priority queues In this queuing scheme mode lower priority fra...

Page 24: ...DiffServ If 802 1p Tag Priority and IP ToS DiffServ are both enabled you have to decide a priority between those two settings Enable Use tag fields for priority mapping when both field types are prese...

Page 25: ...levels of authentication are provided in Switch Management administrator level and user level Administrator level allows you to monitor and configure all functions of Switch Management and the user le...

Page 26: ...IP address here to filter the illegal access Only the IP address in following table can be allowed to access Managed Switch Before UPDATE the setting you have to tick the Active the rule checkbox othe...

Page 27: ...192 168 0 1 Mask 255 255 0 0 Modbus Net ID 1 Serial Port Setting COM1 baudrate 115200 8bit none patity check 1 stopbit COM2 baudrate 115200 8bit none patity check 1 stopbit Redundant Setting Ring Pai...