6. LED function description 

The LEDs are used to indicate meaningful status. Please refer below for the detailed description 

of LEDs. 

 

 

l

 

PWR (Power OK, Yellow) 

It shows the status of internal power of this  module. This LED will  be turned on when the 

power is good. 

l

 

TER (Terminator On, Yellow)

 

It shows the status of on board termination resistor. This LED will  be turned on when the 

termination resistor is enabled. 

l

 

LNK (Link, Green)

 

This LED will be turned on when the communication is successfully established. 

l

 

ERR (Communication Error, Red)

 

This LED will be turned on when the slave module receives an error frame such as a CRC 

error which means the the communication quality has been influenced by external noise. 

l

 

DI00~DI31 (DI status, Green/Yellow) 

The LED will  be turned on when the corresponding DI channel  is turned on. The color of 

the LED will be Green when the corresponding DI is configured as NPN input and it will be 

Yellow when the corresponding DI is configured as PNP input. 

 

7. Rivision History 

Rev 1.0    2015/04/10 Initial Version 

 

ГК

 

Атлант

 

Инжиниринг

 – 

официальный

 

представитель

 

в

 

РФ

 

и

 

СНГ

 

+7(495)109-02-08 [email protected] www.bbrc.ru 

Summary of Contents for MN-3253 Series

Page 1: ...MN 3253 Series User s Manual Version 1 0 Distributed Motionnet 32 ch Isolated DI Module 7 495 109 02 08 sales bbrc ru www bbrc ru...

Page 2: ...325x is 15 1us If 64 modules have been connected signals for 2048 points on 64 modules can be sent and received within 0 97 msec The update of the I O status is completed automatically through the Mot...

Page 3: ...or switch Communication Speed Selectable 2 5 5 10 or 20 Mbps by DIP Switch Cyclic Scan Time 15 1 s per device 20 Mbps Power Voltage Range 24VDC 5 1000V isolated Power Consumption 2W Max Protection Rev...

Page 4: ...circuit of MN 3253 Series Digital Input Control Circuit DICOM DI Internal Circuit 10 30V Power Source 4 7 kOhm Switch Control Circuit DICOM DI Internal Circuit 10 30V Power Source 4 7 kOhm Switch NPN...

Page 5: ...ct to CN1 CN2B Left Pin Assignments 1 2 E24V External 24V Connect to CN1 3 DICOM2 Common terminal of DI08 DI15 Input 4 11 DI08 DI15 Digital input Ch 08 15 Input 12 13 EGND External Ground Connect to C...

Page 6: ...r The on board termination resistor is enabled when the switch is set to ON Please be sure to enable the termination resistor only on the last slave module of each line No Name I O Note 1 2 N C 3 Data...

Page 7: ...it is set to ON 7 S0 8 S1 Speed Selection Every slave module should use the same communicaiton speed as the one set in the master card in a Motionnet communication line for proper operation Table belo...

Page 8: ...LNK Link Green This LED will be turned on when the communication is successfully established l ERR Communication Error Red This LED will be turned on when the slave module receives an error frame such...