background image

P7

 

 

8. Learn IR Commands

 

 
In the section 

“Test and Save Learned IR Commands”

 of the utility: 

(1) Select the item in “Device Name” and “Command Name” combobox. 
(2) Click “Learn On” button to enable IR learning mode (LN LED is ON). 
(3) Aim the emitter head of the remote control (RC) to the “IR Input” of 

the IR-210 (distance less than 3 cm) and press the remote control 
button which is to be learned in a short time. After IR learning is 
finished, the TR/LN LED is OFF.   

(4) Select IR Output 1 in the output channel combobox. 
(5) Aim the IR emitter, which is plugged in IR Output 1 jack, to the IR 

receiver of the controlled device. Click “Run Command” button to 
check the effectiveness of the IR learning command. Repeat (2) and 
(3) if no action on the device. 

(6) Click “Save this Cmd” button. 
(7) Repeat the above (1)~(6) to finish IR learning. 
 
Besides, the color rectangle (marked a blue dotted frame) means:   

 

Red: Learning data is saved in the item of “Command Name”. 

 

Yellow: Get learning data form IR-210. The data is buffered and lost 

when selecting other item of “Command Name”. 

 

White: No learning data saved in the current item of “Command 

Name”. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

≤ 3 cm

 

Summary of Contents for IR-210

Page 1: ...ge includes the following items IR 210 CA 0910 1 CA IR SH2251 2 CA IR SH2251 5 2 Technical Support service icpdas com www icpdas com Resources How to search for drivers manuals and spec information on...

Page 2: ...the position of normal operation mode OP 2 Serial Wire Connection to PC Use the RS 232 cable CA 0910 to establish the wire connection between IR 210 and PC as shown in the following figure The DB9 9...

Page 3: ...3 3 Plug in an IR Emitter Cable Plug the IR emitter cable CA IR SH2251 5 into the 3 5 mm jack of the IR Output 1 4 Power Wire Connection Connect the power supply cable 10 30 VDC to the power connector...

Page 4: ...b page of the product 6 Serial Communication to the Module Select IR 210 in the Module combobox Select the default communication settings Baud rate 115200 bps Parity None Data bits 8 Stop bits 1 and M...

Page 5: ...ntity Please click the Set Device IR Command Quantity button to open the setup window Three steps to bet set Step 1 Set device quantity 1 Set the Device Quantity to be 1 2 Press the Set button 3 Press...

Page 6: ...Enter Device Name and IR Command Quantity 2 Press the Set button 3 Press the Next right arrow button Step 3 Set each IR command name The prefix number e g 1_Play is the number of an IR command stored...

Page 7: ...R Output 1 in the output channel combobox 5 Aim the IR emitter which is plugged in IR Output 1 jack to the IR receiver of the controlled device Click Run Command button to check the effectiveness of t...

Page 8: ...R Commands to IR 210 to download the IR commands to the IR 210 10 Test IR Commands Go to the Test IR Commands in IR 210 section 1 Select IR Command No 2 Select Output Channel to 1 Aim the IR emitter h...