
iNS-316 User Manual
Copyright
©
2022 ICP DAS CO., Ltd. All Rights Reserved.
- 39 -
5. PoE function configure
5.1 RTC
Correct system time is essential to network communication and PoE power management. Configure
the system time correctly before you run the module on the network, iNS-316 provide Automatic
synchronization method to set iNS-316 system time, when iNS-316 Web login, it will auto sync PC
system Time to iNS-316
5.2 Power Schedule
You can configure a weekly schedule for each PoE port individually to reboot the attached devices.
The iNS-316 will check the schedule every hour on the hour. If the checkbox for reset function is
selected, the power on a POE port will be turned off and turned on again for specified time interval
Step1: Select the PoE port number, setting Enable/Disable and the period between turning off the
PoE power and turning it back on again.
Item
Description
Port
Select sechedule port number.
Port Power On Sechedule
Sechedule Enable/Disable select, default Disable.
Port Power Reset Schedule
Power reset delay time, default 10 Sec.
Step2: Click the small box for enabling or disabling the reset function at specfied times.
Step3: Click “update settings” to update the revised settings.