iNS-308   

User Manual 

 

Ver. 1.0.0, Dec. 2022

 

 
 
 
 

 

W

ARRANTY

 

All products manufactured by ICP DAS are warranted against 

defective materials for a period of one year from the date of 

delivery to the original purchaser. 

 

W

ARNING

 

ICP DAS assumes no liability for damages consequent to the use 

of this product. ICP DAS reserves the right to change this manual 

at any time without notice. The information furnished by ICP DAS 

is believed to be accurate and reliable. However, no 

responsibility is assumed by ICP DAS for its use, nor for any 

infringements of patents or other rights of third parties resulting 

from its use. 

 

C

OPYRIGHT

 

Copyright ©  2021 by ICP DAS. All rights are reserved. 

 

T

RADEMARK

 

Names are used for identification only and may be registered 

trademarks of their respective companies. 

 

C

ONTACT 

U

S

 

If you have any questions, please feel free to contact us via email 

at:   

[email protected] 
 

 

S

UPPORT

 

iNS-308 

Summary of Contents for iNS-308

Page 1: ...any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use nor for any infringements of patents o...

Page 2: ...2 Power Schedule 29 5 3 PoE Power Limit 31 6 Advanced Ethernet configure 32 6 1 Loop Detect 32 6 2 Broadcast storm filter 32 7 Modbus Information 33 7 1 What is Modbus TCP IP 33 7 2 Modbus Message Str...

Page 3: ...er Ethernet PoE devices such as wireless access points APs IP cameras and IP phones to the network In compliance with the IEEE 802 3at standard each PoE port ensures the PSE function and provides up t...

Page 4: ...ing List The shipping package includes the following items Quick Start x 1 iNS 308 Note If any of these items are missing or damaged please contact the local distributor for more information Save the...

Page 5: ...t allows users to easily configure monitor and control the module from a remote location using a web browser 2 Power On Off Schedule An individual power on off schedule is provided for each PoE port o...

Page 6: ...E port you can configure the schedule through a web browser to reset your devices regularly and keep them working in good condition 4 Dual Redundant Power Input The iNS 308 has dual redundant power in...

Page 7: ...protection it also provides user defined PoE power output limit so that if the PD device is damaged or short circuited the power will be cut off PoE in time to protect other devices 7 Advanced Ethern...

Page 8: ...r Color status Description P1 Green On Power is being supplied to power input PWR1 Off Power is not being supplied to power input PWR1 P2 Green On Power is being supplied to power input PWR2 Off Power...

Page 9: ...100 Mbps Off Link to 10 Mbps 3 PoE Status Indicator iNS 308 has 8 Port 10 100Mbps PoE Port independent PoE status LED for per port when PoE detect the PD device LED will turn on LED Indicator Color S...

Page 10: ...3az this provides power savings during idle network activity Processing Type Store forward MAC Addresses 16K Frame Buffer Memory 4Mbit Isolation 1500 Vrms 1 minute LED Indicators Status PWR1 PWR2 Faul...

Page 11: ...All Rights Reserved 11 2 3 Ethernet and PoE Pin Out The pinout follows the Alternative A of IEEE 802 3af 802 3at standards Please see the details in the following table Pin No Ethernet PoE 1 Tx V 2 T...

Page 12: ...sure that the network settings on the Host PC have been correctly configured and are functioning normally Ensure that the Windows firewall or any Anti Virus firewall is properly configured to allow in...

Page 13: ...te at https www icpdas com en product guide Software Utility_Driver eSearch__Utility Step 2 Install the eSearch Utility Follow the instructions in the eSearch setup wizard to complete the installation...

Page 14: ...55 0 0 Step 5 Assign new network settings and then click the OK button Enter the relevant values for the IP Address Subnet Mask Gateway etc and then click the OK button The new settings will take effe...

Page 15: ...a web browser Step 8 Change password upon first login The default password for logging in to the iNS 300 web page is Admin You will be prompted to change your password upon first login or when the pa...

Page 16: ...configuring and managing module settings through a browser 4 1 Home The Home page is the startup page when you log into the module It displays detailed information about the module and the connection...

Page 17: ...mit W this function can not used for CDPL mode Current mA The current of connected PoE devices unit mA Watt W The power consumption of connected PoE devices unit W TEMP Display iNS 308 PoE Port inside...

Page 18: ...edule for PoE powered device s in a week The first section provides PoE Port select schedule Enable Disable and reset delay configure interface Whan Power On Schedule set to Enable and Power schedule...

Page 19: ...ve a dynamic IP address from a DHCP server or select static IP to manually assign an IP address to the module here Item Description Address Type Static IP Manually set the IP Address Subnet Mask and D...

Page 20: ...from the Address Type drop down menu Step 2 Click the Update Settings button to complete the configuration Static IP Configuration If Static IP is selected you have to assign an IP address a subnet m...

Page 21: ...the UDP configuration function Web Auto logout Set the automatic logout time The user will be log out after the predetermined period of inactivity on web interface has elapsed Alias Name Assign the a...

Page 22: ...Default Settings Step 1 Click the Restore Defaults button Step 2 Click OK on the pop up dialog box Step 3 Search the iNS 300 series module in the eSearch Utility to confirm if the factory default sett...

Page 23: ...right 2022 ICP DAS CO Ltd All Rights Reserved 23 Rebooting the Module Step 1 Click the Reboot button in the right field of Force Reboot Step 2 After the module restarts reload the web interface and lo...

Page 24: ...rmware by clicking the Reboot button in the Firmware Update section via the network without manual adjustment Note that the iNS 300 series module needs to be connected to the same network as your comp...

Page 25: ...basic parameters and Trap IP Address check the Enable SNMP item and click the Update Settings button to enable the function Note Modify the SNMP Enable status please reboot the iNS 308 to activate th...

Page 26: ...he Allow IP List only clients that have an IP address within the filter list can access the iNS 300 series module Item Description Add IP to the List Enter the new IP address to the Allow IP List Dele...

Page 27: ...assword on the Password page Step 1 Enter your current password in the Current password field Step 2 Enter your new password in the New password field 1 12 alphanumeric characters are allowed Step 3 E...

Page 28: ...iNS 308 User Manual Copyright 2022 ICP DAS CO Ltd All Rights Reserved 28 4 7 Logout Click Logout on the navigation bar to log out of your account It redirects you to the login page...

Page 29: ...o reboot the attached devices The iNS 308 will check the schedule every hour on the hour If the checkbox for reset function is selected the power on a POE port will be turned off and turned on again f...

Page 30: ...Manual Copyright 2022 ICP DAS CO Ltd All Rights Reserved 30 table provide bulk selection functionality Click Toggle On Off or Toggle Reset will select all time at a day Click 0 to 23 will select all d...

Page 31: ...efined by af at sets the corresponding power upper limit When the device load exceeds too much it will power off and retry to protect the device Please refer to the following table for the class class...

Page 32: ...308 provided broadcast storm protect function after checking broadcast storm filter in home page the iNS 308 will actively control the broadcast type packets packet Destination Address is MAC FF FF FF...

Page 33: ...ode Wizcon ElUTIONS and Wonderware etc can be used to easily integrate serial devices via the Modbus protocol 7 1 What is Modbus TCP IP Modbus is a communication protocol that was developed by Modicon...

Page 34: ...data to be returned and an error checking field The Modbus TCP Message Structure The Leading 6 bytes of a Modbus TCP Protocol Query Transaction identifier Assigned by the Modbus TCP master client Prot...

Page 35: ...een correctly transmitted Code Function 01 0x01 Read Coils status Readback DO values 02 0x02 Read Input Status Read DI values 03 0x03 Read Holding Registers Readback AO values 04 0x04 Read Input Regis...

Page 36: ...Address 2 Byte Byte 02 high byte Byte 03 Low byte 04 05 Number of Points Channels 2 Byte Byte 04 high byte Byte 05 Low byte Response Byte Description Size Value 00 Net ID Station Number 1 Byte 1 to 2...

Page 37: ...te Byte 03 Low byte 04 05 Number of Points Channels 2 Byte Byte 04 high byte Byte 05 Low byte Response Byte Description Size Value 00 Net ID Station Number 1 Byte 1 to 247 01 Function Code 1 Byte 0x02...

Page 38: ...yte 1 to 247 01 Function Code 1 Byte 0x03 02 03 Starting AO Address 2 Byte Byte 02 high byte Byte 03 Low byte 04 05 Number of Registers Channels 2 Byte Word Count Byte 04 high byte Byte 05 Low byte Re...

Page 39: ...unction Code 1 Byte 0x04 02 03 Starting AI Address 2 Byte Byte 02 high byte Byte 03 Low byte 04 05 Number of Registers Channels 2 Byte Word Count Byte 04 high byte Byte 05 Low byte Response Byte Descr...

Page 40: ...3 Low byte 04 05 Output Value 2 Byte 0xFF 00 sets the output to ON 0x00 00 sets the output to OFF Byte 04 high byte Byte 05 Low byte Response Byte Description Size Value 00 Net ID Station Number 1 Byt...

Page 41: ...Byte Byte 02 high byte Byte 03 Low byte 04 05 Output Value 2 Byte Byte 04 high byte Byte 05 Low byte Response Byte Description Size Value 00 Net ID Station Number 1 Byte 1 to 247 01 Function Code 1 By...

Page 42: ...te count 1 Byte n Points 7 8 07 Output value n Byte A bit corresponds to a channel A value of 1 for a bit denotes that the channel is ON while a value of denotes that the channel is OFF n 1 Byte 07 da...

Page 43: ...Registers Channels 2 Byte Byte 04 high byte Byte 05 Low byte 06 Byte count 1 Byte n Points 7 8 07 Register Values n Byte n 1 Byte 03 high byte n 2 Byte 04 Low byte n m Byte m 1 high byte Byte m 2 Low...

Page 44: ...R W 00042 1 Ethernet Broadcast storm filter 0 Disable 1 Enable R W 3xxxx AI address Base 0 Address CH Description Range Access Type 30000 30007 8 PoE Port Current mA 2 Byte DEC mA R 30032 30040 8 PoE...

Page 45: ...ts Reserved 45 4xxxx AO address Base 0 Address CH Description Range Access Type 40000 40007 8 PoE Host Power output Limit 1 4W 2 7W 3 15 5W 4 30W R W 40032 1 Ethernet Link status Configure 0 auto nego...

Page 46: ...iNS 308 User Manual Copyright 2022 ICP DAS CO Ltd All Rights Reserved 46 Revision History Revision Date Description 1 0 0 Dec 2022 New...