background image

 

I-7052 

8 Ch DI DAQ Module- QuickStart (Jul/2016)  

ICP DAS USA, Inc.

 

www.icpdas-usa.com

 | 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717

 

 

7. For I-7000 modules, DCON utility pro terminal can send command to the module. 
See user manual Sections 2 for details command. 
 
Configure the module: sending the %AANNTTCCFF command. See user manual 
Section 2 for details.  
 
Read data from the input channels:  send either the #AA or #AAN command to the 
module.  
 

 

 

8. 

If user doesn’t know command, user can select Address and ID, it will show some 

refer commands as below. User can select necessary command to test or debug 
modules. 

 

Summary of Contents for I-7052

Page 1: ...ently designed to provide signal conditioning system monitoring and safe value settings I 7052 is a cost effective solution for a wide range of valuable industrial control signals and systems The DCON utility can help users to configure and test I 7052 Isolated Digital Input modules Plenty of library functions and demo programs are provided to let users develop programs easily under Windows Linux ...

Page 2: ... Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 2 3 Block Wiring Diagram 4 Default Settings Default settings for the I 7000 DIO modules are as follows Module Address 01 DIO Type Type 40 Baud Rate 9600 bps Checksum disabled ...

Page 3: ...le follow the steps below 1 Connect the digital output 2 Connect the module to the RS 485 network using the DATA and DATA terminals If the host is only equipped with an RS 232 interface then an RS 232 to RS 485 converter will be required 3 Connect the module to the power supply using the Vs and GND terminals Note that the voltage supplied should be in the range of 10 to 30V DC ...

Page 4: ...4309 Narbonne Ave Suite 200 Lomita CA 90717 4 4 Open DCON utility pro click on COM port first icon It can select multi options such as Baud Rate Protocol Checksum and Format to search module The default settings for the module can be found in Section 3 Click OK after selecting the COM port setting ...

Page 5: ... 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 5 5 DCON utility pro will search for the selected COM port according the setting previously set DCON Utility Pro supports DCON and Modbus protocol for all ICPDAS and the others modules 6 Configuration I O module setting on PC ...

Page 6: ...ommand to the module See user manual Sections 2 for details command Configure the module sending the AANNTTCCFF command See user manual Section 2 for details Read data from the input channels send either the AA or AAN command to the module 8 If user doesn t know command user can select Address and ID it will show some refer commands as below User can select necessary command to test or debug modul...

Reviews: