P5
Step 4: Connect the fiber port, CAN port, power line
and frame ground of these I-2533T-FD.
The pin assignment and wire connection are as follows. When
finished, run your application with the I-2533T-FD.
Port Name Description
USB
USB
Used for configuration utility
CAN
CAN_L CAN_Low, signal line of CAN port.
CAN_H CAN_High, signal line of CAN port.
CAN_GND CAN_Ground, ground voltage level
of CAN port.
Fiber
TxD
Transmit optic data.
RxD
Receive optic data.
Power
+Vs
Voltage Source Input. +10V
DC
~
+30V
DC
.
GND
Power Ground.
F.G.