3.4. Address (Group number) Setting 

 

 

The group number setting table for 16-group system is shown as 

follows. Each setting includes two consecutive group numbers. S4, 

S5, and S6 are used for 128-group system. Although the settings for 

128-group system are omitted here, they are similar to other 

jumpers that construct a binary code for address.   

 

RA0 

RA1 

 

RA8 

RA9 

 

RA2 

RA3 

 

RA10 

RA11 

 

RA4 

RA5 

 

RA12 

RA13 

 

RA6 

RA7 

 

RA14 

RA15 

   

S3 

S2 

S1 

S3 

S2 

S1 

S3 

S2 

S1 

S3 

S2 

S1 

S3 

S2 

S1 

S3 

S2 

S1 

S3 

S2 

S1 

S3 

S2 

S1 

ГК

 

Атлант

 

Инжиниринг

 – 

официальный

 

представитель

 

в

 

РФ

 

и

 

СНГ

 

+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru 

Summary of Contents for FR-32R

Page 1: ...he right to change this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use not f...

Page 2: ...e of FR 32R 5 3 2 Pin Assignment 6 External Power supply and signals connection 6 Additional FRnet signal connectors 6 I O connectors 7 3 3 Interface Circuit 8 3 4 Address Group number Setting 9 3 5 C...

Page 3: ...en do not feel that they are using remote IO modules The FRnet input modules can connect with the FRnet output modules through the twisted 2 wire bus without a CPU module to become a MagicWire applica...

Page 4: ...x switching voltage 125Vdc 270Vac Max switching current 5A 100 000 operations min at full load Life expectancy 20 000 000 operations min at no load Release time 5 ms Control logic TTL low Relay on Pow...

Page 5: ...of FR 32R Connectors for FRnet quick connection Group number setting JP2 CH17 CH32 External Power and FRnet wiring interface Speed and Hold state setting JP9 Termination resistor setting CH1 CH16 7 4...

Page 6: ...ction J1 Additional FRnet signal connectors All FRnet A signals are internally connected together and all FRnet B signals are connected together too Following two connectors are used for FRnet quick c...

Page 7: ...7 I O connectors CN1 CN2 The CMnn and NOnn in these figures represent the COM and the N O pins of channel nn respectively 7 495 109 02 08 sales bbrc ru www bbrc ru...

Page 8: ...8 3 3 Interface Circuit 7 495 109 02 08 sales bbrc ru www bbrc ru...

Page 9: ...S5 and S6 are used for 128 group system Although the settings for 128 group system are omitted here they are similar to other jumpers that construct a binary code for address RA0 RA1 RA8 RA9 RA2 RA3...

Page 10: ...es are listed in the following table The standard speed 250K bps is set by having a jumper at CK0 position In the following table the jumper at HOLD position determines what kind of the output status...

Page 11: ...rmination resistor LED Each LED indicator has a label expressing its function Note that the Communication Run LED and the Error LED indicate the quality of the communication When FRnet is running norm...

Reviews: