7.2. CAN Pair Connection Application
The CAN pair connection application of the ECAN-200-FD module is used to implement
communication between two ends of CAN network via Ethernet. It is implemented via UDP
protocol for CAN Network #1 can communicate with CAN Network #3 or #4 and CAN Network #2
can also communicate with CAN Network #3 or #4 in the same manner.
CAN Network #1
CAN Network #3
CAN Network #2
CAN Network #4
ECAN-200-FD #1
ECAN-200-FD #2
IP Address
192.168.255.1
IP Address
192.168.255.2
Port1 Settings (CAN Network #1)
Port1 Settings (CAN Network #3)
Local TCP/UDP Port
10001
Local TCP/UDP Port
10001
Application Mode
UDP Mode
Application Mode
UDP Mode
Remote Device IP
192.168.255.2
Remote Device IP
192.168.255.1
Remote Device Port
10001
Remote Device Port
10001
Port2 Settings (CAN Network #2)
Port2 Settings (CAN Network #4)
Local TCP/UDP Port
10002
Local TCP/UDP Port
10002
Application Mode
UDP Mode
Application Mode
UDP Mode
Remote Device IP
192.168.255.2
Remote Device IP
192.168.255.1
Remote Device Port
10002
Remote Device Port
10002