background image

13 

 

13 

 

 

 

4.5 SMS Notification 

 

If  MMS  notification  is  OFF,  device  would  send  SMS  notification  to  SOS  number  with 
message” Alarm” when the alarm is triggered. 

4.6 Dialing Notification 

 

When alarm is triggered, device can auto dialing to the SOS numbers, user can monitor the 
live voice after pick up the call.    Factory status is OFF. 

4.7 Power Disconnect Alert 

 

Alarm  message  “Main  power  is  interrupted,  please  pay  attention!”  would  be  sent  to  SOS 
numbers via SMS if the power is disconnect/fail.   

 

If device is ON, when power is connect again, alarm message “Main power connection has 

been restored

” would be sent to SOS numbers via SMS. Factory status is OFF. 

4.8 Low Battery Alert 

 

Alarm message “Alarm battery voltage is low, please charge in time!” would be sent to SOS 
numbers if the inside battery voltage is under 3.7V.   

4.9 System Shut Down Alert 

 

Alarm message “System shutdown!” would be sent to SOS number via SMS when the system 

Summary of Contents for Wireless Home Alarm

Page 1: ...1 1 Wireless Home Alarm User Manual V2 1 Copy right reserved...

Page 2: ...m 12 4 4 MMS Notification 12 4 5 SMS Notification 13 4 6 Dialing Notification 13 4 7 Power Disconnect Alert 13 4 8 Low Battery Alert 13 4 9 System Shut Down Alert 13 4 10 SD Card Failure Alert 14 4 11...

Page 3: ...19 Server with DNS service Setting 18 5 20 Real time Photograph Setting 18 5 21 Check GPRSParameters 18 5 22 Check SET Parameters 19 5 23 Check Base Parameter 19 5 24 Check Firmware Version 19 5 25 C...

Page 4: ...4 4 1 Accessories Please make sure that all accessories are complete Pictures are for indication and illustration purposes only...

Page 5: ...SM Frequency GSM 850 900 1800 1900MHz GPRS Class 12 Image Resolution 640 X 480 Image Sensor COMS 0 3 Mega Pixels External storage SD card 2G Maximum 4G Battery Capacity 800mAh Working Voltage Current...

Page 6: ...to or recording video Solid orange Arming OFF Disarming Quick flashing Arm 10 seconds countdown Green LED GSM signal Status Implication Quick flashing interval 0 1s Searching GSM Initialization Slow f...

Page 7: ...u can install the SIM card battery and storage card Also make sure to always turn off the power before installing or replacing the SIM card and battery To remove the back cover Make sure your device i...

Page 8: ...ce depends on many factors including network configuration signal strength and usage patterns For more information see Battery Safety in the Appendix Warning To reduce risk of fire or burns Do not att...

Page 9: ...the notch to remove it Storage Card To install a SD card Make sure that your device is turned off and then remove the back cover Locate the SD card slot on the upper part of the exposed right panel I...

Page 10: ...nger and breach of approval and warranty terms of this device Notice Device would auto reboot after power recovery if the device is off by battery run out of power 3 5 Setting Before Use Please add th...

Page 11: ...matically If not the device would enter voice monitoring status When the device is in arming status dial the device number from SOS phone and hang up in 10 seconds the device would enter disarming sta...

Page 12: ...record time can be customized via SMS command ALARMSET number of pictures record time Number of pictures 0 5 0 means no pictures when alarm is triggered Video record time 0 300s 0 means not video rec...

Page 13: ...message Main power is interrupted please pay attention would be sent to SOS numbers via SMS if the power is disconnect fail If device is ON when power is connect again alarm message Main power connec...

Page 14: ...monitoring the voice device would hang up the call and handle the alarm information first 4 12 Photograph SOS number can take the real time picture via SMS command PHOTO or 333 pictures would be sent...

Page 15: ...8362 5 3 Set APN Command Reply SMS Description a APN apnname b APN apnname user pwd Set Success ega apn kktcell egb apn orange orange orange 5 4 Set MMS Command Reply SMS Description a MMS centerAddre...

Page 16: ...ent Reply SMS Description a GMT time bearing time zone b GMT time bearing time zone half time zone Time zone E 8 0 Timezone E W Standard Timezone 1 12 Half hour Timezone 15 30 45 ega GMT E 8 egb GMT E...

Page 17: ...00 5 14 Set Dialing Notificaton SMS Content Reply SMS Description CALLSET call time Set Success Time 0 3 0 means off dialing notification Factory CALLSET 0 eg CALLSET 3 5 15 LED Indicator Setting SMS...

Page 18: ...P port protocol0 Set Success ega DSERVER 1 www ydpat com 8011 0 egb DSERVER 0 211 154 135 113 8011 0 5 20 Real time Photograph Setting SMS Content Reply SMS Description a PHOTO b 333 MMS with pictures...

Page 19: ...BY NORMAL GPRS Link Up GSM Strong GN 1 GT E 8 LG 0 SE 0 AT 3 60 PT 1 CT 0 IL 300 CO ON CI OFF HE 1 Battery status GPRS status GSM status server status time zone language resolution IR alarm status ph...

Page 20: ...e of other accessories may lead to void warranty service The manufacturer is not liable for any damage resulted from using accessories from other channels New battery should be fully charged 12 hours...

Page 21: ...r SIM card without caller ID display function Active function of caller ID display Fail to connect network Wrong installation of SIM card Check SIM card installation Filth on the SIM card iron surface...