OPERATION
DISPLAY
STEPS
Setup Menu
Press to Key
History Data
Press
to display
Setup menu
.
The following options are available (using the or buttons)
0. Pipe parameter
1. System setting
2. Calibration
3. Output setting
4. History data
Setup menu
Press , Select
4. History data
, then to display:
0. By Day :
Display Totalizer flow for days.
1. By Month :
Display Totalizer flow for months.
2. By Year :
Display Totalizer flow for years.
History data
0.By Day
1.By Month
2.By Year
0. Pipe parameter
1. System setting
2. Calibration
3. Output setting
4. History data
14
23-0
166
© Icon Process Controls Ltd.
Data Logging Setup Menu
Model
Pipe OD
OD Range
A (mm) Max
C(mm)
UF500-15
16.5 - 23
86
106
UF500-25
30-35
91
106
UF500-40
48-54
110
106
UF500-50
58-68
126
130
UF500-50
88-96
154
150
UF500-100
½"
1"
1-½"
2"
3"
4"
108-116
177
174
B(mm)
52
58
78
91
119
143
Dimensions
A
C
A
B
42
UltraFlo
®
UF-500
Clamp-On Ultrasonic Flow Meter Sensor