When in counting or stand by mode, short Press the
[SET]
key to switch lo total interface, press and hold the
[CLEAR]
key for more than 5s, the LCD wil display in full screen, after 5s, the LCD screen will automatically return to the standby interface,
and the total accumulation has been cleared.
Clear the Data of Total Measurement
www.iconprocon.com | [email protected] | 905.469.9283
04
Turbine Electronic Flow Meter
TC SERIES
QTS
FLOW RATE
RESET
TOTAL
x 100
L
GAL
CAL
PTS
L
GAL
QTS
FLOW RATE
RESET
TOTAL
x 100
L
GAL
CAL
PTS
L
GAL
CLEAR
SET
When in counting or standby mode, press the
[SET]
key to switch the interface between flow rate, total flow (shown as below).
Switch the Interface between Flow Tate, Total Flow
QTS
FLOW RATE
RESET
TOTAL
x 100
L
GAL
CAL
PTS
L
GAL
QTS
FLOW RATE
RESET
TOTAL
x 100
L
GAL
CAL
PTS
L
GAL
SET
When in counting or stand by mode, press and hold the
[SET]
key for more than 5 seconds to the setting interface (shown as
below), press the
[CLEAR]
key to modify the flashing digit value, press the
[SET]
key to switch the flashing digit, when
finish setting, long press the
[SET]
key to save and exit the setting molde, or if you don't have any futher operation, the system
will automatically save and exit the setting mode after 30 seconds.
For example :
The current value is 1000, which means 1000 pulses correspond to 1 L
Pulse Number Setting
PULSE SETTING INTERFACE
QTS
FLOW RATE
RESET
TOTAL
x 100
L
GAL
CAL
PTS
L
GAL
CLEAR
SET
SET
SET
When in counting or stand by mode, press and hold the
[SET]
+
[CLEAR]
keys for more than 5 seconds to the unit
setting interface, press the
[CLEAR]
key to switch the unit between
L
,
GAL
,
QTS
,
PTS
(shown as below), when finish setting,
long press the
[SET]
key to save and exit, or if you don't have any futher operation, the system will automatically save and exit
the setting mode after 30 seconds.
Measurement Unit Setting
CLEAR
CLEAR
SET
SET