Carefully retighten the locking screw.

We  recommend  you  to  use  lacquer/thread  locker  to  secure  the  locking  screw  of  the  switching  unit  after  carrying  out  individual 
adjustments.

Close the cover until it locks into place.

Dimensions

Pipe Size

Connection

D

Max. Flow

m3/h, Water

Rising

Flow Rate

L/min, Water

AA

(mm)

L

(mm)

D

(mm)

Falling

Flow Rate

L/min, Water

½ - 2"

3"

4"

4"

6"

8"

Model

FES-005-2

FES-005-3

FES-005-4

FES-005-41

FES-005-6

FES-005-8

½" NPT

½" NPT

½" NPT

½" NPT

½" NPT

½" NPT

20

30

40

70

110

120

1 | 2

3 | 6

4.8 | 8

4.5 | 5.5

8 | 11

18 | 24.2

0.9 | 1.9

2.9 | 5.5

4.6 | 7.5

4 | 5

7.8 | 10

17.5 | 24

27

27

27

27

27

27

52

52

52

112

112

112

12 X 20

12 X 20

12 X 20

12 X 80

12 X 80

12 X 80

1

16.3

98

127

AA

AA

D

D

d

d

L

L

www.iconprocon.com | [email protected] | 905.469.9283

08

Plastic Flow Switch

FES SERIES

The switching unit does not need to be adjusted when the customer requests a factory set switching point.

Locking Screw

High flow rate

Low flow rate

Setting Range

Red
White

Locking Screw

High flow rate

Low flow rate

Setting Range

Red
White

Make Contact (Red arrow)

Break Contact (White arrow)

Summary of Contents for truflo FES Series

Page 1: ...Plastic Flow Switch FES SERIES Operating Manual www iconprocon com sales iconprocon com 905 469 9283 Plastic Flow Switch FES SERIES...

Page 2: ...ciple Pump Protection Technical Specifications Installation Electrical Connection Dimensions Warranty Returns and Limitations 03 04 04 04 05 05 06 08 09 Table of Contents www iconprocon com sales icon...

Page 3: ...r the respective literature it is the responsibility of the customers to determine the suitability of the product for the specific application The flow switches are state of the art devices This conce...

Page 4: ...ir device functioning The technical data of special versions customised versions can deviate from the details in these instructions Please observe the details on the type plate Caution Danger of death...

Page 5: ...any magnetic particles e g welding residue The straight in and outlet pipe in front of and behind the flow switch has to be at least 5 x ID The nominal installation position of the flow switch is an u...

Page 6: ...s 7 and subsequently connect the wires as displayed in the connection diagram see Fig 4 Danger of death due to electrical voltage Work on electrical installations may only be carried out by qualified...

Page 7: ...ion the switching unit until the red or white arrow are visible at the entry of the switching contact guide for a desired make contact or break contact respectively You can use the arrow length to mak...

Page 8: ...005 8 NPT NPT NPT NPT NPT NPT 20 30 40 70 110 120 1 2 3 6 4 8 8 4 5 5 5 8 11 18 24 2 0 9 1 9 2 9 5 5 4 6 7 5 4 5 7 8 10 17 5 24 27 27 27 27 27 27 52 52 52 112 112 112 12 X 20 12 X 20 12 X 20 12 X 80 1...

Page 9: ...cted to electrical mechanical or chemical damage due to improper accidental or negligent use 3 have been modified or altered 4 anyone other than service personnel authorized by Icon Process Controls L...

Page 10: ......

Reviews: