background image

S.T.INNOVATORS

 

ICON rev.may 2010

 

10

 

 

Figure 5 

 
 

Tube Box 

GU50 (V5L)
 
GU50 (V4L)
 
GU50 (V4R)
 
GU50 (V5R)

GU19-1 (V3L) 

 

6N1P-EV (V2L) 

 

6N1P-VI (V1L) 

 

EM800 (V6L) 

 

EM800 (V6R) 

 

6N1P-VI (V1R) 

 

6N1P-EV (V2R) 

 

GU19-1 (V3R) 

Summary of Contents for STEREO TUBE POWER AMPLIFIER

Page 1: ...STEREO TUBE POWER AMPLIFIER STEREO TUBE REAMPLIFIER USER S MANUAL S T I N N O V A T O R S S O F I A 1 5 0 5 1 T Z A R I C H I N A S T R T E L 8 7 0 2 1 5 6 F A X 9 7 3 3 7 2 7...

Page 2: ...S T INNOVATORS ICON rev may 2010 2...

Page 3: ...3 7 Tubes Connections and Switches location 14 8 How to Connect for Stereo 16 9 How to Operate the ICON 18 Power On Stand by and Off 18 Input Switch 18 10 Setting the Tubes Bias 19 11 Specifications 2...

Page 4: ...arisee avec un prolongateur une prise de courant ou un autre sortie de courant sauf si les lames peuvent etre inserees afond ans en laisser aucune partie a decouvert 7 Unplug this equipment during lig...

Page 5: ...pped 24 Do not attempt to service beyond that described in the operating instructions All other service should be referred to qualified service personnel 25 When replacement parts are required be sure...

Page 6: ...S T INNOVATORS ICON rev may 2010 6 STEREO TUBE POWER AMPLIFIER...

Page 7: ...r cables are 50 feet 38 1m or less use at least 14 Gauge If your loudspeaker cables are 100 feet 76 2m or less use at least 12 Gauge 5 Pin configuration for the XIR Balanced Input connectors on the IC...

Page 8: ...may 2010 8 4 ICON Stereo Tube Power Amplifier Dimensions The following dimensions can assist in determining the best location for your ICON Front View of ICON Figure 1 Rear View of ICON Figure 2 Side...

Page 9: ...hat is your case then follow the next steps Note Gloves or a soft cloth will prevent fingerprinting of the Tubes during their installation 1 Using an appropriate screwdriver remove screw from the bott...

Page 10: ...S T INNOVATORS ICON rev may 2010 10 Figure 5 Tube Box GU50 V5L GU50 V4L GU50 V4R GU50 V5R GU19 1 V3L 6N1P EV V2L 6N1P VI V1L EM800 V6L EM800 V6R 6N1P VI V1R 6N1P EV V2R GU19 1 V3R...

Page 11: ...of the Tubes during their installation Power Output Tubes 1 Orient the Chassis so that the Front Panel of the Amplifier is facing you 1 Locate a GU50 V5L Power Output Tube Refer to figure 6 2 On the...

Page 12: ...e Small Input Tubes There are two different types of Small Input Tubes 6N1P EV and 6N1P VI used in each channel Tube type can be found on the outside of the Tube The ICON will not function if they are...

Page 13: ...knob 6 Location and Ventilation The ICON can be placed upright on a table or shelf standing on its four feet Adequate ventilation extends the trouble free life of the ICON The suggested minimum space...

Page 14: ...ion 1 3 5 2 4 6 7 9 11 8 10 12 13 Figure 9 1 3 GU50 output tubes for left channel 2 4 GU50 output tubes for right channel 5 6 GU19 1 driver tubes 7 8 6N1P EV input tubes 9 10 6N1P VI input tubes 11 12...

Page 15: ...elects between the BALANCED or UNBALANCED INPUTS 8 9 RIGHT and LEFT outputs connections for loudspeakers 10 grounding connector 11 power synchronization connector with preamplifier 12 Input 12V trigge...

Page 16: ...r or prepared section of the cable end into the terminal side access hole and tighten the terminal cap until the cable is firmly clamped into the terminal so the wires cannot slip out Banana plug conn...

Page 17: ...S T INNOVATORS ICON rev may 2010 17 Connect to AC Outlet Connect to AC Outlet Figure 11 Stereo Connection...

Page 18: ...uld be shut down when not being used This will greatly prolong tube life A standby mode has been provided for short term use between listening sessions so that the amp will remain in a warmed up state...

Page 19: ...benefit to this approach is that should a tube fail prematurely the single tube can be replaced without having to purchase a matched set Use the following procedure to set the tube bias WARNING There...

Page 20: ...ping Factor Greater than 8 Input Impedance 100 k unbalanced inputs 200 k balanced inputs Power Supply Impulse power supply 120 V from 100 to 135 V 50 60 Hz at 10 230 V from 195 to 260 V 50 60 Hz at 5...

Page 21: ...n damage to the Vacuum Tubes and possibly the ICON It is very important that the four feet are attached to the bottom of the equipment This will ensure the proper equipment location on the bottom pad...

Page 22: ...S T INNOVATORS ICON rev may 2010 22 STEREO TUBE PREAMPLIFIER...

Page 23: ...uld not be applied until all the system components are connected together Failure to do so could result in malfunctioning of some or all of the system s normal operations 2 ICON Stereo Tube Preamplifi...

Page 24: ...4 200 mm 232 mm 365 mm 475 mm 3 ICON Dimensions The following dimensions can assist in determining the best location for your ICON Front View of ICON Figure 1 Rear View of ICON Figure 2 Side View of I...

Page 25: ...peration ensures the longest possible operating life for any electronic instrument Do not install the ICON Pre directly above a heat generating component such as a high powered amplifier If all the co...

Page 26: ...t for AUX 5 Right and Left first output 6 Right and Left second output 7 GND terminals 8 Power synchronization connector with power amplifier 9 Output 12V trigger for remote power control 10 Power sup...

Page 27: ...S T INNOVATORS ICON rev may 2010 27 7 How to Connect the ICON Preamplifier Connect to AC Outlet Connect to AC Outlet Figure 6...

Page 28: ...ights to indicate the preamplifier is Switched Off The Blue LEDs inside the Power On and Source Selection Switch lights to indicate the preamplifier is connected to AC Power Select the desired source...

Page 29: ...tilation extends the trouble free life of the ICON Pre The suggested minimum space for operating the ICON Pre is 70 cm in width 60 cm in depth and 60 cm in height Always allow air to flow through the...

Page 30: ...io A Weighted High Level 90dB Phono 82dB Input Impedance High Level 24K ohms unbalanced Phono MM 47K ohms 120pF Adj 50 680pF Maximum Input Signal High Level 10V Unbalanced Phono MM 50mV Voltage Gain H...

Page 31: ...the proper equipment location on the bottom pad Failure to do this will result in shipping damage Four M6x50 mm screws must be used to fasten the unit securely to the Shipping Skid Failure to do this...

Page 32: ...INNOVATORS ICON rev may 2010 32 Contacts S T Innovators Ltd 1 Tzarichina Str 1505 Sofia Bulgaria Phone 359 2 870 21 56 Fax 359 2 973 37 27 e mail st_innovators mail orbitel bg www stinnovators com Ab...

Reviews: