13
1 2
4
icOn Smart TVC preamplifier
Input GND switch
To reduce ground loops and hum. Suggested: HARD, when the in-
put and output grounds are directly connected. Lift: not connected
- output ground is floating. Soft: output ground connected through
a 22 Ohm resistor to input ground. The input grounds are con-
nected to the chassis all the time.
Power switch
You can leave icOn switched on using the sleep mode for deactiva-
tion
USB
For firmware upgrade only
12V DC trigger output (optional)
It is active when icOn is switched on and is not in sleep mode.
Max. load current: 100 mA - please don’t feed other equipment
from it! You can use mono or stere 3.5 mm jack plug.
Connection:Tip: +12V, sleeve GND, ring is not connected.