Technical Specifications
Output
Output
4-20mA + Pulse Relay | RS-485
Ambient Temperature
-15 ... +50°C
Storage Temperature
-15 ... +50°C
Current output QA
0/4...20 mA
Lower- and upper limit adjustable,
Ground connected to supply ground
Error Signal according to NAMUR NE43 with 4 … 20 mA
Digital output Q1/2
via transistor npn- and pnp-logic
max. 30V/100mA
output voltage according to DIN 19240:
5V means LOW
12V means HIGH
Short cut resistant
Frequency 0....10kHz
Measuring Deviation
± 2% of reading ± 3 mm/s
Option: ± 1% of reading ± 3 mm/s
Reference conditions (VDE/VDI 2642)
Repeatability
0.5%
Data Interface
Data Interface for Parameterize
Electrical
Power Input
24VDC | 3.6W
Power Supply
18-30VDC
Connection
plug 5 pins, plug 8 pins, 10-wire Teflon cable (5m)
Display
LCD Display
Simultaneous Display of volume Flow, Quantity, bar graph, lighted
Standards and Approvals
CE | FCC | RoHS Compliant
www.iconprocon.com | [email protected] | 905.469.9283
05
Ultrasonic Flow Meter
UltraFlo
®
2000 SERIES
General
Material
HDPE
Protection Class
IP67 | NEMA 4X
Medium Temperature
-20 - 160°F | -29 - 107°C
Measuring Range | GPM | LPM
0.8 - 80 | 3.0 - 300
Max. Pressure | Non-Shock
100 psi | 7 bar
Process Connection
GF External Thread 2"
Dimensions | L | W | H | mm
220 | 95 | 98
Weight | lbs
2.2
Summary of Contents for truflo UltraFlo 2000 Series