 PROGRAMMING EXAMPLE DUAL DISPLAY DEVICE:

Set the device to de-energise the relay after 150 hours.

Press  “

4

”  repeatedly until “Set” + “hour”  is displayed.

Use “

S

” and “

T

” buttons to change the value to “150”.

Press  “

4

” to display the next  menu item.

Press  “

4

”  repeatedly until  “r.Fun” is displayed.

Use “

S

” and “

T

” to change the value to “OPEn”.

Press and hold “

4

”  to exit the menu

PROGRAMMING EXAMPLE SINGLE DISPLAY DEVICE:
Set the device to de-energise the relay after 150 hours.

Press “MENU” to display “Set”.
Press “SELECT”. Use the “+” and “-” buttons to change the value to “150”.
Press “ENTER” to return to the menu. “CLr” is displayed.
Press “MENU” twice. “r.Fun” is displayed.
Use  “+” and “-” to change the value to “OPEn”.
Press “ENTER.
Press “BACK”.

Please Note:
· If the display is configured to indicate remaining time, and the lapsed hours is greater than the set point

value, the display will indicate zero.

· Once 9999 hours have lapsed, the counter will NOT roll over to zero. (It will remain at 9999 until cleared.)

Specifications:
Set point:

0 – 9999 hours

Accuracy:

±0.05%

DUAL Display DEVICE Resolution : 1 second

hours are displayed on the upper display,
minutes & seconds on the lower display

SINGLE Display DEVICE Resolution:

1 hour (minutes and seconds if “SELECT” is pressed, or time < 1hour)

Input voltage:

±15% of rated voltage

Led indication:

Relay status