Description:
The timer is active as long as the “RUN” terminals are shorted.
The timer increments every second until it reaches 9999 h, 59m & 59 sec.
The setpoint can be set with values from 1 second to 9999 hours.
The lapsed time may be cleared by shorting the “CLR” pins, or via the menu.
During a power failure the lapsed time is saved to non-volatile memory.
When power is re-applied the timer continues where it left off. The power may be disconnected indefinitely without loss of data.
The relay functionality may be reversed.
The display may be set to indicate lapsed or remaining time.
A separate “total hours“ counter with a maximum
DUAL DISPLAY DEVICES:
999999
SINGLE DISPLAY DEVICES
9999 hours is also included..
.
Menu options:
· Set point for minutes and seconds (“SEt” + “SEC”)(default:0 min & 0sec)
(press “
S
” or “
T
” to view & make adjustments)
Once the lapsed time is greater than the pre-set hours, minutes & seconds,the relay will change state until the counter is
cleared (via software, or by shorting the “CLR” pins).
Set point for hours (“SEt” + “hour”) (default:0 hours)
(press “
S
” or “
T
” to view & make adjustments)
Once the lapsed time is greater than the pre-set hours, minutes & seconds,the relay will change state until the counter is
cleared (via software, or by shorting the “CLR” pins).
· Clear counters (“CLr”)
Press “
S
” and “
T
” to clear the lapsed time.
· Total number of hours (“tot”) (not adjustable)
Select this setting to view the total number of hours the device has run. This counter is only reset during a full device reset.
See “rest” setting. When the value exceeds 4 digits, the display alternates between the first 3 digits of the value (displayed in
position 1,2 and 3 on the display), and the second 3 digits (displayed in position 2,3 and 4 on the display).
· Relay functionality (“r.Fun”) (default: CLOSE)
Once the pre-set number of hours is reached, the relay will either “CLOSE” or “OPEN”
· Display format (“diSP”) (Default: Lapsed hours)
Set the display to indicate lapsed time (“LA t”), or remaining time (“rE t”) before the relay will switch.
· Reset (“rESt)
Press “
S
” and “
T
” to reset all values to default.
(the total register is also reset to zero).
RUNNING HOUR METER
D3-RHM1
D4-RHM1
P44-RHM1
P49-RHM1
Operating instructions and Guarantee Certificate
www.iconelectronics.co.za
D3
53mm
DIN rail mount
D4
72mm
DIN rail mount
P44
48mmx48mm
panel mount
P49
48mmx96mm
panel mount