icon Audio Stereo 60 MK IV Instruction Manual Download Page 7

Page 7 

Audio  for  a  periodic  service.  In  case  of  difficulty 
you  could  email  or  phone  us.  You  could  also 
return  the  valves  to  Icon  UK  for  testing  free  of 
charge.  Carefully  remove  the  valves  (the 
KT120/KT150s  should  be  held  by  the  base  when 
removing,  to  prevent  damage)  numbering  them 
with a marker or sticker from left to right from the 

front,  in  order  that  that  may  be  replaced  in  the 
same  position.  They  should  be  well  packed  in 
cardboard  &  foam  or  similar,  (Valves  are  very 
rugged if packed properly). 

 

 

 

8 Bias Adjustment  

 

 
 
This  amplifier  uses  the  technically  supe

rior  “Fixed 

Bias” method of setting the output valve idle current. 
For  optimum  performance  and  to  avoid  damage  to 
the amplifier please check this important function at 
least once a month with the built in meter. 

 

Most of the time no action will be necessary, but this 
will give  you  the  reassurance  than  the  valves  are  in 
good condition and working correctly. 

 

When first using the amplifier 

Check that pointer is approximately in the black section. 
Small  variations  have  no  effect.  But  any  valve  reading 
“high” should be reduced. It will take a few weeks for the 
valves  to 

“burn  in”  and  settle  down  after  which  little 

adjustment will be needed. 

 

For occasional checking:  

The triode switch should be set to UL, unless in constant 
triode use. 
With  the  amplifier  warmed  up  (15  mins)  and  with  the 
volume at zero, Rotate the bias knob to check V1,2,3,4. 
This will measure the bias current and give a visual read 
out.  The  optimum  reading  is  when  the  pointer  is  in  or 
close to the black section of the dial (= approx. 47ma).  

It  is  important  to  note  that  if  all  four  valves  read 
slightly  high  or  slightly  low  this  is  normal  and  may 
be  your  local  mains  power  variation. 

If  this  happens 

regularly the bias should be adjusted. 
If one or more valves give unstable readings the valve is 
probably  faulty.  This  may  be  proved  by  swapping  the 
valves  around,  or  trying  replacement  valves.  In UK  Icon 
Audio will test your valves free of charge. 
As  the  valves  age  the  reading  of  each  valve  will  vary. 
This  may  be  adjusted  by  slowly  rotating  the  bias  screw 
for each valve until the reading is in the black mark. 
A small flat blade screwdriver is all you need. 

 

If  you  are  unsure  about  any  aspect  contact  your 
retailer, Icon Audio or a competent service engineer. 
You  are  welcome  to  speak  to  one  of  our  engineers 
by phone or email. 
Most  dealers  and  Icon  Audio  are  happy  to  re-bias 
and check you amplifier free of charge.  

 

No reading at all (or 0) may mean a faulty valve or a 
blown fuse s

ee “Valve fuses” under section 7. 

 

9 Replacing the Valves

 

Icon Audio are happy to replace valves and check to 
performance  of  your  amplifier,  and  advise  on  the 
latest  upgrades  available.  If  you  decide  to  do  this 
yourself please read the following notes first. 

Important:  Do  not  attempt  to  change  the 
KT120/KT150s  without  reading  these  notes. 
Failure  to  do  so  could  be  both  dangerous  and 
damaging to the amplifier. 

 

 

Health & safety; High voltages are present inside 
the amplifier and on exposed valve sockets when 
valves  are  removed,  so  take  suitable  care.  It  is 
not  necessary  to  remove  the  bottom  cover. 
Beware  valves  get  hot  in  operation!  Remove 
power cable when changing valves. 

 

Changing valves:

  

As  new  valves  will  have  a  different  reading  it  is 
recommended that you change one, or one pair at a 
time.  Remove  the  first  old  valve  and  fit  the 
replacement.  Switch  on  and  measure  and  adjust 
bias.  Do  not  allow the reading to go  above  100%  as 
this  could  blow  the  fuse. 

Don’t  worry  how  low  the 

reading goes this will not cause damage. Continue in 
the  same  way  and  fit  all  four  valves.  Do  final 
adjustment when the amplifier is fully warmed up. 
If  all  is  well  there  should  be  no  more  than  a  barely 
detectable  hum  from  the  speakers,  and  the  amplifier 
should sound OK When tested. 

 

If  you  cannot  set  the  pointer  to  the  black  mark,  the 
valve is probably faulty/worn or is unsuitable.  
If  the  valves  are  brand  new,  you  will  need  to  check 
again  after  approximately  10  &  100  hours.  Regular 
checking  will  ensure  the  amplifier  gives  the  best 
performance.  

 

To  avoid  damage  to  the  amplifier  and  electric 
shock  hazard  you  must  use  only  valves  marked 
KT120/KT150  (or  direct  equivalent  e.g.  6550). 
KT66s  and  EL34s  are  not  suitable  and  will  be 
overloaded.  6SN7/CV181  or  that  you  know  to  be 
direct equivalents.

 Use only valves which you know 

to  be  new  or  good  condition  and  test  the  amplifier 
thoroughly before resuming normal use.  

 

Replacing the small 6SN7 valves: 

 

All  four  front  sockets  are  6SN7,  different  types  may 
be used but preferably in pairs, the inner pair are the 
first  stage,  with  the  outer  pair  being  2

nd

  stage  and 

phase splitter. No set up is required. Care should be 
taken  when  removing  and  inserting  not  to  bend  the 
pins.  If  this  happens  gently  bend  the  pins  back  into 
shape. 
 

Summary of Contents for Stereo 60 MK IV

Page 1: ...e In addition we have incorporated features like switchable TRIODE mode and adjustable sensitivity well as 4 Ohm outputs to match a wide range of operating conditions In Ultralinear mode the power is...

Page 2: ...Triode mode Run min 8 hour test Check inputs tape monitor Output Valve Bias level Sound Quality Valve Microphony Valve Seating Hum level left right mv mv RF Test Power out 1 kHz 8ohms L R Channel Bal...

Page 3: ...the down position The amplifier should now be working All valves should have a visible orange glow from the cathode heaters With the volume control set to minimum fully anti clockwise there should be...

Page 4: ...ted to these terminals unnecessarily Connecting loudspeakers 4or 8 Ohms The output impedance of the Stereo 60 MK IV has been optimised to work with 3 12 ohm speakers Many modern speakers use a 4 ohm b...

Page 5: ...plified through the speakers with the possibility of damage in some cases The solution is to switch on the preamplifier first with the ST60 MK IV in standby until the preamplifier is working normally...

Page 6: ...be no sound on that channel You can test for this by checking the bias a zero reading would normally mean a blown fuse Also the valve s in question will be much cooler to the touch be careful Replacem...

Page 7: ...gineer You are welcome to speak to one of our engineers by phone or email Most dealers and Icon Audio are happy to re bias and check you amplifier free of charge No reading at all or 0 may mean a faul...

Page 8: ...igh quality metal film wire wound resistors High quality polypropylene audio caps Optional Mundorf Silver Gold audio caps Japanese Blue ALPS volume pot Rubicon Nichichron power capacitors Silver plate...

Page 9: ...f replacement This amplifier is designed for normal domestic hi fi use It is not guaranteed for commercial Public Address use or use in other situations The guarantee becomes void if the unit has been...

Page 10: ...wn with the flaps open 2 Lift the cardboard box off 3 Remove the bottom packing first 4 Turn the unit the right way up and remove the top packing Please be careful not to damage the small tape monitor...

Reviews: