IMPORTANT! READ THIS ALL THE WAY THROUGH FIRST 

 

2 QUICK SET UP GUIDE  

 

Box contents: 

Amplifier,  remote  control,  mains  lead,  manual, 
bias meter. 4x 6AS7 2x 6SN7, 6SL7, 274B/GZ34 

 

1  Unpack  unit  carefully

  and  check  that  it  is  in 

good condition. Transit damage must be reported 
to Icon Audio within 3 days. It is important that you 
keep packaging for warranty/service return.  

 

2 If necessary fit the valves, or check that they 
are  firmly  in  place.  (SEE  DIAGRAM) 

The  larger 

four  6AS7s  should  be  fitted  first  observing  the 
numbers  1,2,3,4  on  the  rear  of  the  valve;  this 
corresponds with the four sockets from left to right 
viewed  from  the  front.  This  is  essential  as  each 
valve  is  ‘set  up’  in  this  position. 

Do  not  push  or 

pull  the  output  valves  excessively  by  the 
glass

,  this  could  cause  the  glass  envelope  to 

become  detached  from  the  base,  damaging  the 
valve. 

Note  the  orientation  of  the 

“spigot”  in 

the middle of the pins which lines up with the 
sockets of all the valves

.  

Then fit single 274B/GZ34 
Then  fit  the  three  smaller  valves  in  the  sockets 
along  the  front  valves  noting  the  numbers.  The 
middle one is a 6SL7, the outside pair are 6SN7. 
The  274B  rectifier  valve  should  be  fitted  in  the 
centre position. 

 

3  Connect  to  source  units

,  e.g.  CD,  Tuner, 

Tape, Phono pre amp (if used) etc via appropriate 
phono sockets. 

 

4  Connect  to  speakers

  making  sure  that  the 

correct impedance (ohms) is chosen, (see back of 
speakers).  Most  modern  speakers  are  6  ohms 
which  so  this  is  not  critical  (see  Ch  3),  if  you  are 
not  sure  start  by  using  the  8 

ohms  (and  “0”) 

terminals. 

Don’t forget to get the correct polarity of 

speaker  cables.  (See  speaker  connections 
chapter). If ‘bi-wiring’ both ‘common’ should go to 
the  black  terminal,  and  both  ‘positive’  (or  red) 
should go to either 4 or 8 ohm terminals. 

 

5  Connect  to  mains

  supply  using  supplied  IEC 

mains  lead  to  220/240v  supply. 

If  for  some 

reason  the  welded  plug  must  be  removed, 
please 

remove 

fuse 

and 

dispose 

of 

immediately.

  (As  they  can  be  a  danger  to 

children  if  plugged  in).  The  replacement  plug 
should be wired in the following way Brown to Live 
terminal, 

Blue 

to 

Neutral 

terminal 

and 

Green/Yellow to Earth. 

 

6A  Put  the  STANDBY  swit

ch  in  the  “up” 

position. 
6B  SWITCH  ON!

  The  front  LED  should  light  and 

the  valves  will  take  approximately  60  seconds  to 
start  working.  All  valves  should  have  a  visible 
orange  glow  from  the  cathode  heaters.  After  60 
seconds  push  the  standby  switch  down.  The 
amplifier should now be working. 

6C  The  Volume

 

control will “re-set” on switch on 

to  aprox  “9pm”  position.  There  should  be  no 

sound  coming  from  the  speakers  except  a  barely 
discernable  gentle  hum.  If  there  are  any 
unexpected  sounds  coming  from  the  speakers, 
switch  off  and  refer  to  the  ‘Trouble  Shooting’ 
section or contact your dealer or Icon Audio. 
If  you  do  not intend to use the amplifier for a few 
hours  you  can  switch 

into  “standby”,  when  it  will 

use  minimal  power  and  be  ready  for  use 
“instantly”. In standby you may hear

 

low distorted 

sound  from  the  speakers  if  you  have  a  source 
playing. This is normal, reduce the volume! 

 

7  Your  unit  should  now  be  functioning

.  If  not 

check 

wiring 

again 

and/Use 

selector/tape 

monitor/volume  to  choose  source  program  and 
suitable listening volume. Do not operate at a high 
volume for the first five minutes to allow the valves 
to warm up properly. 

8,  Remote  Control. 

If  the  batteries  are  OK  (2x 

AAA)  the  LED  should  light  when  any  of  the  keys 
are pressed. A little skill is needed in pointing and 
pressing, as the unit has a motorised “pot” which 
may not be as responsive as your TV. 

 

Please note all these things are normal for 

valve amplifiers: 

A, Valves can get very hot, BEWARE! 
B, The power transformer will get quite warm 
C, The amplifier may smell slightly for a few weeks. 
D, Mobile phone ‘breakthrough’ is normal. 
E,  Valves  may  make  a  ‘tinkling’  sound  when 
warming up and cooling down. 
F,  The  volume  control  may  sometimes  appear  to 
sound ‘Scratchy’, this is not a fault!  
G, Valves occ

asionally “Pop” or “Crackle”. If this is 

regular 

problem 

it 

could 

be 

your 

CH 

boiler/cooker/fridge etc. (see trouble shooting). 

 

8 Health and Safety

. The valves when  operating 

have  high  surface  temperatures.  Keep  out  of 
reach  of  children  and  pets.  The  use  of  the 
supplied  guard  is  recommended  in  these 
circumstances.  Always  unplug  when  making 
adjustments. 

Like  all  amplifiers  there  are 

potentially  lethal  high  voltages  inside  (over 
400v  DC),  which  when  switched  off  can  take 
twenty  minutes  to  discharge!

  Do  not  remove 

bottom  panel  unless  you  are  a  competent 
engineer.  There  are  no  user  serviceable  parts 
inside. 

Like 

other 

household 

electrical 

appliances 

do  not  leave  unattended  whilst 

switched  on.

  Do  not  adjust  the  output  valve  grid 

bias  pre  sets  without  reference  to  the  manual. 
Incorrect  adjustment  could  cause  the  valves  to 
overheat,  with  resulting  in  damage  to  valves  and 
amplifier.  

 

To  maintain  the  best  performance  of  the 
amplifier  you  should  check  the  bias  of  the 
output  valves  from  time  to  time  (say  twice  a 
year). Full details will be found in section 7. 

Summary of Contents for Stereo 40 6AS7 Limited Edition

Page 1: ...our ears attune themselves to the new sound Your source loudspeakers and room acoustics will also affect the sound before it finally reaches your ear Some people find a small adjustment in re position...

Page 2: ...wiring check Check Triode mode Run min 6 hour test Check inputs tape monitor Output Valve Bias level mv Sound Quality Channel Balance Valve Microphony Valve Seating Hum level left right mv RF Test LE...

Page 3: ...switch down The amplifier should now be working 6C The Volume control will re set on switch on to aprox 9pm position There should be no sound coming from the speakers except a barely discernable gent...

Page 4: ...Page 4...

Page 5: ...of cables therefore the benefits of very exotic cables may be wasted But this is personal taste Icon or your dealer will advise you As all cables have losses keeping the speaker cables short is best I...

Page 6: ...e and reliability The upgrade valves supplied with selected models are the result of careful comparison with other makes But beware paying excessive amounts for New Old Stock second hand or Fake copy...

Page 7: ...may easily be re configured for 110 120v ac Contact us for more information 6 Bias Checking Adjustment The bias voltage for this amplifier is 330mv DC The Stereo 40 6AS7 uses the Split Bias method of...

Page 8: ...ALENT US 6080 Russian China 6N5 6N13 DO NOT USE ANY OTHER OUTPUT VALVE AS DAMAGE WILL RESULT 8 Replacing the small valves 6SL7 centre and 6SN7 valves Neither of these requires any set up procedure It...

Page 9: ...countries applicable guarantee law applied You are advised to inform us of any change of address or ownership in order that we may keep you up to date of any upgrades or improvements Check our websit...

Reviews: