icon Audio Stereo 25 MK II Quick Start Manual Download Page 6

Page 6 

Hum Problems 

If  you  experience  hum,  try  disconnecting  all  inputs,  if 
hum persists this is probably an amplifier fault.  
If  not,  identify  which  input is  causing  hum. Connect  one 
input at a time. A 

common cause is a ‘hum loop’ caused 

by  having  to  many  earths,  and  may  be  identified  by 
unplugging  each  input  source  from  the  mains.  One 
remedy for this is to use an interconnect which only has 
the  screen  connected  at  one  end.  Other  causes  of  low-
level  hum  can  be  from  adjacent  equipment,  so 
experiment  with  moving  equipment  around  to  see  if  this 
makes the hum better or worse. 

 

Valve Replacement 

(see also section 7) 

Recommended 

valves 

are 

EL34/6CA7/KT77 

or 

KT88/6550, 6L6, 5881 and KT66 are also compatible. 
You will need  a QUAD  MATCHED  SET for best results, 
otherwise the bias voltage may vary too much.  

If  replacing  with  the  same  type  and  brand  no 
adjustment 

is 

normally 

necessary, 

although 

checking  is  advisable  to  confirm  the  amplifier  is 
working correctly (8v dc on each valve, see below). 

If  changing  to  a  different  type  you  must  check  the  bias 
voltage  with  a  suitable  meter  as  damage  and  poor 
performance may result. 

 

Service: 

Should  you  suspect  a  problem,  you  could 

return  the  unit  to  Icon  Audio  for  a  periodic  service  or 
return the valves for testing 

free of charge

.  You should 

carefully remove the valves (the output valves should be 
held  by  the  base  when  removing,  to  prevent  damage) 
numbering  them  with  a  marker  from  left  to  right  as  you 
do  so  in  order  that  that  may  be  replaced  in  the  same 
position.  They  should  be  well  packed  in  cardboard  & 
foam  or  similar,  and  returned  to  Icon  Audio  for  testing. 
(Valves are very rugged if packed properly). 

 

Mains Supply 

This amplifier is either hard wired to work on 230/240v or 
115vac 

50/60Hz 

depending 

upon 

country. 

The 

transformer may be re-configured for either voltage by a 
qualified engineer. Contact for more information. 

 

6 Bias Adjustment and setting 

Read these notes all the way through first. 
If  you  are  unsure  about  any  aspect  contact  your 
retailer, Icon Audio or a competent service engineer. 

 

The  Stereo  25  uses  the  Icon 

“semi  fixed  bias’  mode  of 

valve  operation.  There  is  only  one  adjustment,  this 
affects  all  valves. 

This  will  only rarely  need  adjusting 

if at all

 as the amplifier can compensate for some valve 

deterioration.  This  has  the  advantage  of  higher  power, 
and  cooler  running.  However  occasionally  (say  once  a 
year, or if you suspect a problem) it is advisable to check 
the bias reading using the optional meter to ensure best 
performance from the amplifier. This is a safe procedure 
which involves measuring 

8v DC

 in the four sockets next 

to each output valve and adjusting if necessary. 

 

1, Tools you will  need: The optional  meter  or one set to 
measure approx approx 20v (DC), and a small flat blade 
screwdriver.  Adjustment  is  done  at  zero  volume  with 
speakers connected. Check and adjust (if necessary) as 
soon  as  the  amplifier  starts  working  and  again  30  mins 
later.  Icon  Audio  can  supply  a  suitable  meter  for  £15  + 
P&P (at 01/2021), or you have one already. 

 

2,  Connect: 

the  black  probe  to  the  chassis  ‘earth’  by 

unscrewing  the  ‘0’  speaker  terminal  and  tightening  the 

probe  in  the  exposed  hole.  And  the  other  in  the  test 
socket  adja

cent  to  the  valve  on  test.  Set  the  ‘Icon’ 

meter to 20v or 

the ‘black mark’. See pics. 

 

 

Making the ‘earth’ connection. 

3, Checking Bias: You should get a reading of ideally 
8v  if  each  valve  is  conducting  correctly.  But  this  will 
vary  from  about  6v  to  9v.  About  -20%  should  be  the 
maximum  variation.  Bear  in  mind  that  your  mains 
voltage  fluctuations  can  affect  your  readings  up  to 
about 10%. There is no provision to  adjust individual 
valves, which is not necessary on the ST25. 

 

 

Showing a probe reading 1

st

 output valve 

 

4, Adjusting: If  all the valves are high  or low, set the 
8v by using the single adjusting screw. If one valve is 
significantly  higher  or  lower,  then  it  may  be  faulty  or 
life  expired.  The  adjustment  is  very  sensitive  so 
adjust  very  carefully.  If  the  reading  appears  a  little 
unstable  this  is  normally  due  to  mains  fluctuations. 
The Stereo 25 uses semi-fixed bias, where the output 
valve  is  allowed  to  find  its  own  individual  fine  bias 
level. Only occasional checking should be necessary. 
Bear in mind that valves with an output of up to 25% 
below  the  others  are  unlikely  to  have  much  of  an 
audible effect of the sound at normal listening levels. 

If  changing  to  a  different  type  of  valve  turn  the 
voltage  down on the old valves first to a low  level  to 
avoid  overloading  the  power  supply  with  the  new 
valves.  Allow  new  valves  to  warm  up  for  5  minutes 
then set to correct level. 

 

*Triode Operation 

If  this  model  was  ordered  with  100% 

“Pure  Triode” 

modification  (see  page  2)  the  output  will  be  reduced 
to about 19 Watts per Channel making it better suited 
to  higher  efficiency  vintage  designs.  All  other 
specifications and instructions remain the same. 
The  ST25  is  normally  configured  for 

“Ultralinear” 

operation  (50%  Triode  50%  Pentode)  giving  about 
30W  output.  This  is  a  good  compromise  for  power, 
distortion and sound quality.  
This  modification  is  easily  made  or  reversed  by  an 
engineer. More information available on request. 

Summary of Contents for Stereo 25 MK II

Page 1: ...recordings are have a good balanced sound therefore an amplifier which faithfully reproduces the input signal will also reproduce imperfections in the tonal balance and the recording itself Setting u...

Page 2: ...ng check Triode modified Yes No Power output 1 kHz 8 L R Run min 8 hour test Check all inputs Output Valve Bias level V Sound Quality Channel Balance Valve Microphony Valve Seating Hum level left righ...

Page 3: ...nal and Green Yellow to Earth terminal 6 SWITCH ON The LED mains indicator should light up After about 40 seconds the amplifier should start working All valves should have a visible orange glow from t...

Page 4: ...with a volume control the volume control will be virtually invisible to the pre amplifier if turned to the full clockwise position If you have too much gain back off the volume no more than necessary...

Page 5: ...cket mains fuse at the back of the amplifier To gain access remove the mains lead The fuse is in a small plastic drawer which forms part of the socket assembly To open insert a flat bade screwdriver o...

Page 6: ...ing the optional meter to ensure best performance from the amplifier This is a safe procedure which involves measuring 8v DC in the four sockets next to each output valve and adjusting if necessary 1...

Page 7: ...low the reading goes this will not cause damage Do final adjustment when the amplifier is fully warmed up If all is well there should be no more than a barely detectable hum from the speakers and the...

Page 8: ...roved by Icon Audio 10 Packing Instructions It is essential that the original custom box and packing be kept for shipping as this provides vital protection during transit Do not write on box but use l...

Reviews: