icon Audio MB30m Instruction Manual Download Page 6

*See engineers notes at rear

  

 

Page 

‘Burning in’ 

Although the amplifier should sound good within 
about 15 mins it can take up to an hour to sound 
at its best 

when new

 and will take several months 

of regular use before it is fully ‘run in’. Like the 
ageing of wine, the biggest change occurs in the 
first month but continues at a slower and slower 
rate for 2-3 years. The sound will become more 
mellow and musical over time. 

 

Upgrading Valves! 

Quality valves should sound better and have a 
better service. The valves supplied with selected 
models are the result of careful comparison with 

other makes. But beware of paying a premium for 
“New Old Stock” valves where you may be paying 
for rarity value and not performance. Icon Audio 
can recommend and supply a range of standard 
and upgrade valves. Importantly valves supplied 
will be tested and listened to before despatch so 
you can be sure of the best sound quality. 

 

Cabinet Care 

To remove dust we suggest gentle brushing of the 
paintwork with a soft paintbrush. Other marks can 
usually be removed with a damp cloth. Never use 
anything wet on the amplifier, and always clean 
with the power disconnected.  

5 Trouble Shooting 

1. Amplifier Dead 

Check the 2 amp mains fuse in the IEC socket at the

 

back of the amplifier. To gain access, remove the mains 
lead. The fuse is in a small plastic drawer, which forms 
part of the socket assembly. To open insert a flat blade 
screwdriver or similar and prise open. 

The fuse in use 

is the innermost

 the outer is a spare. Should the 

replacement fuse also blow there is a fault you should 
disconnect from the mains and seek qualified help or 
Icon Audio. Replacements should be 2 Amp ‘anti-surge’. 
The fuse in the wall plug should be a 5 amp fuse, 
although unlikely to fail, this should be checked if the 
amplifier fuse is OK. 

 

2. No sound 

Have you selected the right input? Is the “Tape Monitor” 
switch on? Are all the connections OK? Is everything 
switched on? Are the speakers connected? 

Distorted sound. 

Could be your source, the speakers or the amplifier, 
check all wiring, and try swapping things around to 
eliminate or prove which component if the problem. 
Left or right amplifier? If both probably the source unit. 
Try another source. If one amplifier is distorted check the 
bias. No bias reading means either a fuse blown or a 
faulty valve. Distorted sound at higher volumes may be 
because one of the KT120 valves failing. A symptom of 
this could be unable to bias properly. Refer to an 
engineer or to Icon Audio.  

 

3. Hum Problems 

If you experience hum, try disconnecting the input, if it 
clears it is NOT the amplifier, but some cause external to 
the MB30m and further advice should be sought from 
your dealer or Icon Audio. By elimination find out which 
unit is causing this. Interconnects MUST be well 
screened (some exotic ones are not!). 
If hum persists with no input this is may be a fault. 

 

4. External hum causes;

 

Identify which input is causing hum. Connect one input at 
a time. A common cause is a ‘hum loop’ caused by 
having too many earths, and may be identified by 
unplugging each input source from the mains. One 
remedy for this is to use an interconnect which only has 
the 

screen connected at one end

. Other causes of low-

level hum can be from adjacent equipment, so 
experiment with moving equipment around to see if this 
makes the hum better or worse. “Unscreened” 
interconnects WILL cause hum with this amplifier. Only 
use screened interconnects. 

Never disconnect a mains earth. It is there for your 
protection! 

 

5. Strange noises coming from speakers 

Disconnect the pre-amplifier. If the noise disappears 
the fault is elsewhere. Turn volume to minimum on 
unused pre-amplifier input, if the noise disappears, 
the fault is with the source or the connection. If noise 
persists, the problem is with the pre-amplifier. 

 

If a whole output valve glows red (other than the 
heater), often accompanied by a hum through the 
speakers, switch off immediately, and refer to Icon 
Audio or a service engineer, as this could be valve 
failure. 

 

6. Service: 

Should you suspect a problem, you could 

return the unit to your dealer or Icon Audio for a 
periodic service or return the valves for testing free of 
charge. You should carefully remove the valves (by 
pulling the base, not the glass). Numbering them with 
a marker from left to right as you do so in order that 
that may be replaced in the same position. They 
should be well packed in cardboard & foam or 
similar, and returned to Icon Audio for testing. 
(Valves are very rugged if packed properly). 

 

*Mains Supply 

This amplifier is hard wired to work on 230/240v ac. 
The transformer may be re-configured for 110/120v 
ac by a qualified engineer. See engineers notes or 
contact Icon Audio for more information. 

 

This manual is provided for guidance only, and is not 
intended as a comprehensive service manual. In 
case of problems you should refer to your dealer or 
directly to Icon Audio.

 

 

Summary of Contents for MB30m

Page 1: ...out anything please contact your dealer or one of our team Valve amplifiers do need a little more attention than their solid state counterparts but the sonic results are well worth it In this manual we have tried to include everything that you need to know Please let us know if you find any errors or feel that we have missed anything out The MB30m is a Single Ended one output valve triode UL power...

Page 2: ...libration ma Run min 10 hour test Check input Output Valve Bias level v Sound Quality Channel Balance Valve Microphony Valve Seating Hum level L R mv RF Test LED brightness Serial No sticker and recorded Mains voltage 110 120 230 240V IEC Mains Fuse A Soft Start Fitted N A Sales invoice Bottom label Credit card receipt Customer survey form Bias meter Transformer Protection N A Upgrades Output valv...

Page 3: ...sensitive to noise so therefore may be placed close to each other similar to a conventional power amplifier Or alternatively place adjacent to each loudspeaker in order to keep the loudspeaker cable to a minimum They should be placed on a flat surface to allow a gap underneath to aid ventilation ...

Page 4: ...eutral terminal and Green Yellow to Earth terminal 6 SWITCH ON The meter should light up and a visible glow may be seen inside the valves when viewed from certain angles After about one minute the amplifier should now be working With the pre amp volume control set to minimum there should be no sound coming from the speakers except a barely discernible hum If there are any unpleasant sounds coming ...

Page 5: ...t of phase with the sound stage inside out with reduced bass If you are unable to check this or confirm the polarity e g if you have built in wiring a test disc will be helpful If you are bi wiring you can independently use either 4 or 8 ohms for the bass and treble Many modern smaller speakers use a 4 ohm unit If in doubt the heaviest base is the best match depending upon preference and again 4 o...

Page 6: ...gher volumes may be because one of the KT120 valves failing A symptom of this could be unable to bias properly Refer to an engineer or to Icon Audio 3 Hum Problems If you experience hum try disconnecting the input if it clears it is NOT the amplifier but some cause external to the MB30m and further advice should be sought from your dealer or Icon Audio By elimination find out which unit is causing...

Page 7: ...d box with a note detailing the problem which valves you suspect and your contact details We will then contact you with the test results Possible visible valve faults Not all valve faults are visible but KT120s 6SN7s and GZ34s valves should not be used if 1 The silver getter material has turned white or is disappearing air leak 2 The valve rattles excessively a slight rattle is normal 3 There are ...

Page 8: ...lease contact us first 8 Specification Features 100 Pure Class A output power Class A all Triode front end KT120 60w beam pentode output valve 6SN7 CV181 double triodes 1st stage valve Valve rectifier GZ34 5AR4 Output power Triode 16w 11 35v 8 Ohms Ultralinear 27w 14 7v 8 Ohm Oversized choke regulated power supply for both driver and output stage Our own unique designed tertiary wound output trans...

Page 9: ...omestic hi fi use It is not guaranteed for commercial Public Address use or use in other situations The guarantee becomes void if the unit has been modified in any way not approved by Icon Audio 10 Packing Instructions It is essential that the original box and packing be kept in good condition as this provides vital protection from damage during transit Please do not write on box but use removable...

Page 10: ...istor of around 5 10KΩ will speed this up and check that the HT voltage has discharged Amplifier dead Check the 20mm mains fuse in the IEC socket at rear of the amplifier if dead there is a spare included Or the fuse in the plug if applicable If not either check in line power switch fuse adjacent to IEC socket 230v to 115v Conversion Take the precautions as above It is necessary to change the prim...

Reviews: