8
2 LED indicator
2.1
I
N NORMAL OPERATION
•
The red LED shows the state of the relay 2.
•
The green LED shows the state of the relay 1.
2.2
W
HEN THE SELF
-
MONITORING DETECTS AN ERROR
The two LEDs blink quickly (2 or 4 quick flashes followed by a 1 sec break, depending on the detected error).
3 SETTINGS
3.1
ENCODERS
See figures Figure 2and 3, p. 4.
3.1.1
Encoder 1
Besides red LED, at the left facing the housing
Parameter
Value
Unit
Distance
“
movement
”
(relay 2)
60
20
m
Distance
“
presence
”
(relay 1)
10
15
10
15
m
Max. relay hold time
2 4 8 16 2 4 8 16 2 4 8 16 2 4 8 16 min
Encoder position
0
1 2 3 4 5 6 7 8 9 A B C D E F
Factory setting = 0
3.1.2
Encoder 2
Besides green LED, at the right facing the housing
Parameter
Value
Sensitivity
Normal
Low
Self
-
monitoring
Active
Inactive
Active
Inactive
RF channel
1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
Encoder position
0
1 2 3 4 5 6 7 8 9 A B C D E F
Factory setting = 0
Once you have set the requested radar
parameters, place the sticker on the front face to
guarantee its water tightness.
ATTENTION:
manufacturer’s warranty does not
cover radars without sticker!