9
RADAR BOOT UP
1
T
EST MODE
During the boot up, the radar operates in test mode during the first 50 seconds. The radar behaviour can be erratic
due to an evolving calibration procedure.
2
N
ORMAL OPERATION
Once the calibration is done, the radar will automatically switch over to normal operation mode. Only detections
beyond 2.5 meters distance from the radar are validated.
LED INDICATOR
1
I
N NORMAL OPERATION
The LEDs are activated when the relay is activated and are turned on for a minimum of 750 milliseconds.
2
W
HEN THE SELF
-
MONITORING DETECTS AN ERROR
The two LEDs blink quickly (2 or 4 quick flashes followed by a 1 sec break, depending on the detected error).
INSTALLATION GUIDE
1
G
ENERAL
•
Installation height: min. 3.5 m - max. 4.5 m
•
Tilt or inclination angle: The smaller the angle, the further the radar detects but the larger the “no-detection”
zone starting at the foot of the radar pole.
Figure 9: Tilt or installation angle
2
A
SSEMBLY AND MOUNTING
1.
Set the appropriate parameter values with the encoders
and place the sticker.
2.
Fix the radar on the bracket:
α
= vertical radar opening angle (
α
= 45°)
β
= horizontal radar opening angle (
β
= 38°)
tilt = Inclination angle compared to the horizon