4 - 1
SECTION 4. ADJUSTMENT
PROCEDURE
¤
GENERAL CONNECTION
EQUIPMENT
GRADE AND RANGE
EQUIPMENT
GRADE AND RANGE
RF power meter
(50
Ω
terminated)
Measuring range
: 0.1–20 W
Frequency range
: 100–1500 MHz
SWR
: Less than 1.2 : 1
Standard signal
generator (SSG)
Frequency range
: 0.1–1500 MHz
Output level
: –20 dBµ to 100 dBµ
(–127 to –7 dBm)
Spectrum analyzer
Frequency range
: DC–20 MHz
Measuring range
: 0.01–20 V
AC millivoltmeter
Measuring range
: 10 mV to 10 V
External speaker
Input impedance : 8
Ω
Capacity : More than 2 W
¤
REQUIRED EQUIPMENTS
4-1 PREPARATION
RF-C UNIT
(UX-9100)
MAIN-B UNIT
(UX-9100)
[EXT SP (MAIN)]
[1200MHz ANT]
STANDARD SIGNAL GENERATOR
(1–1500 MHz)
RF POWER METER
(20 W/50
Ω)
DO NOT
transmit while
an SSG is connected to
the antenna connector.
AC MILLIVOLT METER
(10 mV to 10 V)
EXT. SPEAKER
(2 W/8
Ω)
3.5(d) mm monoral plug
+
–
+
–