REAR PANEL CONNECTION
To [TX]
OPC-2202
(Option)
OPC-2243
To [ACC]
To
[I/O]
To [TX]
Connects to a dPMR
control unit, if used.
Connects to a 4
˘
external speaker.
Connects to
an RX antenna.
GND
Connects to
a TX antenna
OPC-2203
(Option)
Connects to external
equipment, if used.
OPC-2202
OPC-2203
If external equipment
is used, an OPC-2203
must be used.
Black
Red
30 A
fuses
DC power supply
AC outlet
AC cable
Supplied
DC power cable
13.2 V; at least 30 A
Black
_
Red
+
CAUTION:
NEVER remove the
fuse holders from the
DC power receptacle.
Black
Red
20 A
fuses
DC power supply
AC outlet
AC cable
Supplied
DC power cable
13.2 V; at least 15 A
Black
_
Red
+
POWER SUPPLY CONNECTION
Make sure the repeater's power is turned OFF before
connecting a DC power cable.
CAUTION:
Voltages greater than 16 V DC will
damage the repeater. Check the source voltage
before connecting the power cable.
R
When you disconnect the DC power cable, take care to
not break your fingernail.
q
Push
w
P0
P1
P2
P3
P4
to [MIC] connector
to USB port
OPC-1122U
(USB type)
PC
[PWR]
CLONE SETTING
NOTE:
Before operating the repeater with the power amplifier unit installed, the following settings are necessary
using the CS-FR5000
cloning
software
in addition to the usual repeater settings
.
Refer to the instruction
manual of the CS-FR5000 for more details.
t
u
y
LINE FUSE REPLACEMENT
The UR-PA5000/UR-PA6000 is equipped with 30 A
fuses. If the fuses blow, find and repair the problem,
then install new fuses with the same ratings.
CAUTION: USE
specificed fuses only.
CAUTION: DISCONNECT
the DC power cable
from the amplifier. Otherwise, there is danger of an
electric shock and/or equipment damage.
e
Read all the transceiver’s data before beginning
the setting, even when the transceiver is factory
fresh.
• Click
, or click “
Clone
” in the top menu of the clon-
ing software, and then select “
Read <- TR
” to read.
• While reading or writing the cloning data,
NEVER
turn
OFF the transceiver or the PC, and
NEVER
disconnect
the cloning cable. Otherwise, the data could be lost or
deleted.
r
Open “
Memory CH
,” and set the RF PWR as “
L1
.
”
• Adjust the output power to 5 W.
t
Open “
Ports Setting”
in the
“External I/O”
folder,
as shown below.
y
Set
“Ext.I/O18”
with
“Output”
as In/Out, “
TX
” as
the Function and “
Low
” as the Active Logic.
u
Set “
Ext.I/O21
”
with “
Output
”
as In/Out, “
AUX1
”*
1
as the Function and “
Low
”*
2
as the Active Logic.
*
1
Select a port between AUX1 through 4 that is not se-
lected for other functions.
*
2
For the 100 W output version, select “
High
” as the Ac-
tive Logic.
q
Connect the cloning cable, as illustrated below.
w
Push
[PWR]