33
10
SERVICE MAN MENU
■
SPD adjustment
q
Push [MENU]/[
], [
q
] and [
u
] one or more times
to display the “SERVICE MAN” menu.
w
Hold down [
q
] until the “SPD ADJ.” section be
-
comes highlighted.
e
Push [
t
] [
u
] to enter the pulse rate of the speed
sensor unit (pulse numbers per one nautical mile).
r
Push [MENU]/[
] to return to the normal screen.
■
RANGE selection
SERVICE MAN
SPD ADJ.
HDG ADJ.
0.0
˚
HV
SETUP MEMORY
2 4 0 0 0 MONITOR
HEATER
5 7 3 1 . 0 H
TX TIME
3 0 . 0
OUTPUT
ENGLISH
VOLTAGE
MG
3 4 0
7 5
3 . 0
0 . 5 5
TIMING ADJ.
1/8 3/4
2
6
1/4
1
3
8
1/2 1.5
4
12
16
24
32
36
48
RANGE
*
1
⁄
4
NM range will be skipped.
72
64
q
Push [MENU]/[
], [
q
] and [
u
] to display the
“SERVICE MAN” menu.
w
Hold down [
q
] until the “RANGE” section becomes
highlighted.
e
Push [
p
] [
q
] to choose the selectable screen
ranges with [+]/[
] or [–]/[
] on the dis-
play.
r
Push [
t
] to skip from the range selection, or push
[
u
] to cancel skipping.
t
Push [MENU]/[
] to return to the normal screen.
Selectable ranges:
1
⁄
8
,
1
⁄
4
,
1
⁄
2
,
3
⁄
4
, 1, 1.5, 2, 3, 4, 6, 8, 12,
16, 24, 32, 36, 48*, 64
†
, 72
†
(NM)
*48 NM range is available for the MR-1000TII/TIII.
†
64 and 72 NM ranges are available for the MR-1000TIII only.