2001 NEW
8
27
MAINTENANCE
2001 NEW
2001 NEW
■
Troubleshooting
If your repeater seems is not operating correctly,
check the following points before sending it to an au-
thorized Icom service center.
PROBLEM
Does not turn ON.
N o t r a n s m i t o u t p u t
power, or low output
power.
Sensitivity is low and
only strong signals are
heard.
Does not function, even
if a signal is received.
T h e P C d o e s n o t
recognize the repeater
The settings cannot be
programmed into the
repeater properly.
POSSIBLE CAUSE
• Power connector has a poor contact.
• Blown fuse.
• Antenna or coaxial cable has problems.
• Antenna or coaxial cable has problems.
• Unit initial setting is wrong or duplicated.
• Config. Setting is wrong.
• No check mark (
4
) is applied.
• The USB cable is too long.
• The USB cable is too long.
SOLUTION
• Check the connector pins and then re-
connect the DC power cable.
• Fix the problem, then replace the fuse.
• Check, and if necessary, replace the coaxial
cable or the antenna connector again.
• Check, and if necessary, replace the coaxial
cable or the antenna connector again.
• Set “A” to each voice and data repeater and
never duplicate the initial between voice
repeaters and/or data repeaters.
• Set the corresponding conditions to the
connected repeater combination.
• Apply a check mark (
4
) into the appropriate
connector number.
• Use a shorter USB cable.
• Use a shorter USB cable.
REF.
p. 7
p. 28
pp. 6,
7
pp. 6,
7
p. 23
p. 23
p. 23
p. 9
pp.
25–26
Summary of Contents for ID-RP2C