![background image](http://html2.mh-extra.com/html/icom/ic-r30/ic-r30_service-manual_3576576019.webp)
4-4
ADJUSTMENT
ADJUSTMENT DISPLAY
SETTING CONDITION
VALUE
ITEM
FREQUENCY MODE
SUB
Noise
squelch
42 A NSQL
22.500
FM
145.100 Set the standard signal generator to:
Frequency: The same as the displayed
frequency on the MAIN band.
Modulation: 1 kHz
Deviation:
±3.5 kHz
Level:
–26 dBµ (–133 dBm)
Push
[ENTER].
(Automatic
adjustment)
43 A NSQL
40.100
FM
145.100
44 A NSQL
63.100
FM
145.100
45 A NSQL
92.100
FM
145.100
46 A NSQL
145.100
FM
145.100
47 B NSQL
145.100
FM
145.100
48 A NSQL
217.100
FM
217.100
49 B NSQL
217.100
FM
217.100
50 A NSQL
320.100
FM
320.100
51 B NSQL
320.100
FM
320.100
52 A NSQL
470.100
FM
470.100
53 B NSQL
470.100
FM
470.100
54 A NSQL
650.100
FM
145.100
55 A NSQL
1167.500
FM
145.100
56 A NSQL
2341.100
FM
145.100 Set the standard signal generator to:
Level:
–22 dBµ (–129 dBm)
4-2 ADJUSTMENT (CONTINUED)